User manual
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Triple Crown 3,8 1,4 146
Semi-rapid 1,9 0,45 96
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 30/30 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS
FLOW g/h
Triple Crown 3,8 1,4 98 276
Semi-rapid 1,9 0,45 71 138
Auxiliary 1,0 0,33 50 73
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification EGT7353YOK
Type of hob Built-in hob
Number of gas burners 5
Energy efficiency per gas burner
(EE gas burner)
Left rear - Semi-rapid 52.7%
Right rear - Semi-rapid 52.7%
Middle - Triple Crown 54.3%
Left front - Semi-rapid 52.7%
Right front - Auxiliary not applicable
Energy efficiency for the gas hob
(EE gas hob)
53.1%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
10.2 Energy saving
• Before use, make sure that the burners and pan supports are assembled correctly.
• Use cookware with diameters applicable to the size of burners.
• Center the pot on the burner.
• When you heat up water, use only the amount you need.
• If it is possible, always put the lids on the cookware.
• When the liquid starts to boil, turn down the flame to barely simmer the liquid.
• If it is possible, use a pressure cooker. Refer to its user manual.
www.electrolux.com16