User manual

13
Fig. 3
The manufacturer declines all responsibility if
the accident prevention regulations are not
respected.
Fig. 4
To open the terminal box and reach the terminals
proceed as described below:
- insert the point of a screwdriver into the visible
protruding part of the terminal box;
- exert a light pressure and lift (fig. 4).
Replacement of the voltage cable
The connection of the voltage cable to the appliance’s terminal box is of type “Y” which signifies that its
replacement requires the specific equipment of a technician. If the replacement of the cable is necessary, use
only cables type H 05 VV H2-F O T 105; in both cases, the cables must be of sections suitable to the voltage
and able to support the working heat. Furthermore it is necessary that the yellow/green earth wire be
approximately 2 cm longer than the phase wires (fig. 3). After connection try out the heating elements by
allowing them to function for about three minutes.
This appliance conforms to Directive EEC N. 87/
308 of 2.6.87 relating to the abolition of radio
interference.
FO 0287
FO 0073
Neutral
Earth wire (yellow - green)
Installation
The appliance is of type X and has been designed to
be built into or fitted next to units according to the
regulations in force (IEC 61-80).
The side walls of the unit must not exceed the height
of the appliance’s hob.
Avoid installing the appliance in the proximity of
inflammable materials (e.g. curtains, tea towels, etc.).
Electrical connection
The appliance is predisposed to function with a 220/
230 V monophase voltage tension.
The connection must be carried out in conformity with
the regulations and dispositions of the laws in force.
Before connecting ensure that:
- the limiter valve and the electrical mains can
support the voltage of the appliance (see label).
- the power supply is correctly earthed according to
the regulations in force.
- the plug or omnipolar interrupter used can be
easily reached once the appliance has been
installed.
Fit a sectioned plug to the voltage cable and connect
to a security socket.
If a direct connection to the mains is required an
omnipolar interrupter with a minimum opening of 3
mm between contacts which does not interrupt the
neutral, corresponding to regulations in force, should
be interposed between the appliance and the supply.
The brown coloured phase cable (situated at terminal
“L” of the terminal box) must always be connected to
the network phase.
The voltage cable must always be positioned in such
a manner that it at no point reaches a temperature of
80°C above room temperature.
Instruction for the Installer