User manual

electrolux 15
)
Minimum adjustment screw
Fig. 1
Fig. 2
With the aid of a 7mm box spanner
the burner injectors can then be
unscrewed and replaced by the
appropriate Natuaral gas injectors
(Fig.1).
B. Adjustment of minimum
level
When the hob has been fully installed it will
be necessary to check the minimum flame
setting. To do this, follow the procedure
below.
- Turn the gas tap to the MAX position
and ignite.
- Set the gas tap to the MIN flame
position then turn the control knob
from MIN to MAX several times. If the
flame is unstable or is extinguished
follow the procedure below.
Procedure:
- Re-ignite the burner and set to MIN.
- Remove the control knob and use a
thin bladed screwdriver to turn the
adjustment screw until the flame is
steady and does not extinguish, when
the knob is turned from MIN to MAX.
- The adjustment screw may be
located at the centre of the gas tap
control shaft or on the gas tap body,
left of the control shaft or below
(Fig.2).
- Repeat the adjustment procedure for
all burners.
To adjust the gas rate
To adjust the minimum level of the
burners, proceed as follows:
Light the burner.
Turn the knob on the minimum
position.
Remove the knob.
With a thin screwdriver, adjust the by-
pass screw.
If changing from LPG to natural gas
unscrew about 1/4 turn the by-pass