Gas connection: R 1/2 "
Category: II2H3+
Gas supply: G20 (2H) 20 mbar
Appliance class: 3
By-pass diameters
Burner Ø By-pass in 1/100
mm.
Auxiliary 28
Burner Ø By-pass in 1/100
mm.
Semi-rapid 32
Rapid 42
Gas burners
BURNER
NORMAL
POWER
RE-
DUCED
POWER
NORMAL POWER
NATURAL GAS
G20 (2H) 20 mbar
LPG
(Butane/Propane) G30/G31 (3+)
28-30/37 mbar
kW kW
inj. 1/100
mm
m³/h
inj. 1/100
mm
G30
28–30
mbar
G31
37 mbar
g/h g/h
Auxiliary
burner
1.0 0.33 70 0.095 50 73 71
Semi-rap-
id burner
2.0 0.45 96 0.190 71 145 143
Rapid
burner
3.0 (natural
gas)
2.8 (LPG)
0.75 119 0.286 86 204 200
ENVIRONMENT CONCERNS
The symbol on the product or on its
packaging indicates that this product may
not be treated as household waste. Instead
it should be taken to the appropriate
collection point for the recycling of electrical
and electronic equipment. By ensuring this
product is disposed of correctly, you will
help prevent potential negative
consequences for the environment and
human health, which could otherwise be
caused by inappropriate waste handling of
this product. For more detailed information
about recycling of this product, please
contact your local council, your household
waste disposal service or the shop where
you purchased the product.
Packaging material
The packaging materials are friendly to
the environment and can be recycled.
The plastic components are identified
by marking: >PE<,>PS<, etc. Discard
the packaging materials as household
waste at the waste disposal facilities in
your municipality.
12 electrolux