Wiring diagram
A. IGNITOR SWITCH
B. IGNITOR UNIT
B
L
N
0
1
2
3
4
220/240
A
Fault finding
Preliminary Electrical Systems
Check
Brown
Blue
Green
Yellow
Green
Yellow
Brown
Blue
A. EARTH CONTINUITY CHECK - Appliance must be
electrically disconnected - meter set on W (Ohms) x 1
scale and adjust zero if necessary.
a) Test leads from any appliance earth point to earth
pin on plug. Resistance should be less than 0.1 W
(Ohm), check all earth wires for continuity and all
contacts are clean and tight.
B. INSULATION CHECK - Appliance electrically
disconnected, all switches ON.
a) meter set on W (Ohms) x 1 scale.
Test leads from L to N in appliance terminal block.
If meter reads «0» then there is a short circuit.
b) meter set on W (Ohm) x 100 scale.
Repeat test with leads from L to E. If meter reads
less than ¥ (infinity) there is a fault.
NOTE - Should it be found that the fuse has failed but
no fault is indicated - a detailed continuity check (i.e.
by disconnecting and checking each component) is
required to trace the faulty component.
It is possible that a fault could occur as a result of local
burning/arcing but no fault could be found under test.
However a detailed visual inspection should reveal
evidence of burning around the fault.
START
Isolate appliance
and carry out:
A: Earth Continuity
check.
Has inlet fuse blown?
Carry out:
C: Polarity check.
Electricity supply
should now be
satisfactory.
Carry out:
D: Resistance to
Earth check.
Inlet wiring
faulty.
Rectify any
fault.
Isolate appliance and
carry out:
B: Insulation check.
Rectify any fault
including replacing
fuses as necessary.
NO YES
NO
YES
SOCKET
(face view)
PLUG (with cover removed)
Earth Wire
Green/Yellow
Neutral Wire
Blue
( )
FUSE
( )
E
N
L