User manual

6
Important safety requirements
This hob must be installed by qualified personnel, according to the manufacturers instructions and to the relevant
Australian Standards.
The hob should not be installed in a
bed sitting room with a volume of
less than 20 m
3
. If it is installed in a
room of volume less than 5 m
3
an
air vent of effective area of 110 cm
2
is required. If it is installed in a room
of volume between 5 m
3
and 10 m
3
an air vent of effective area of 50
cm
2
is required, while if the volume
exceeds 11 m
3
no air vent is
required. However, if the room has
a door which opens directly to the
outside no air vent is required even
if the volume is between 5 m
3
and
11 m
3
.
Location
Choose a location free of draughts
and open doors and clear of
combustible materials or other fire hazards such as curtains, etc. The location should ensure convenience of operation
and service. The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or
shower room. Before making the cut out in the worktop ensure that there is a minimum distance of 55 mm. between
the rear edge of the hob and the wall.
A minimum distance of 100 mm. must be left between the side edges of the hob and any adjacent cabinets or walls.
The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 400
mm. If it is fitted below 400 mm. a space of 50 mm. must be allowed from the edges of the hob.
The minimum distance combustible material can be fitted directly above the hob is 700 mm.
TYPE TYPE NOZZLE NOMINAL NOMINAL
OF GAS OF BURNER MARKS GAS PRESSURE
1/100 mm CONSUMPTION kPa
MJ/h
Triple Crown 1.57 13.00
Rapid (large) 1.50 11.00
Semi-rapid (medium) 1.11 6.80 1.00
Auxiliary (small) 0.89 3.80
Triple Crown 0.97 13.00
Rapid (large) 0.93 11.00
Semi-rapid (medium) 0.71 6.30 2.75
Auxiliary (small) 0.55 3.80
NATURAL
GAS
U-LPG
Burner Dia. Tap By-pass
1/100 mm
Auxiliary 28
Semi-rapid 35
Rapid 42
Triple crown 42
Aeration adjustment none
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply
APPLIANCE GAS SUPPLY:
Natural gas 1.0 kPa - Universal LPG 2.75 kPa
Instructions for the Installer
Engineers technical data
OVERALL DIMENSIONS
Width: 860 mm.
Depth: 500 mm.
CUT OUT DIMENSIONS
Width: 830 mm.
Depth: 470 mm.
CLEARANCES REQUIRED WHEN FITTING THE GAS HOB
WITH A COOKER HOOD ABOVE
700 mm
400 mm
100 mm
400 mm
50 mm
50 mm
55 mm
FO 2027*
FO 2028*
700 mm
400 mm
400 mm
100 mm
50 mm
50 mm
55 mm
700 mm
CLEARANCES REQUIRED WHEN FITTING THE GAS HOB
WITHOUT A COOKER HOOD ABOVE