User manual

7
A) End of shaft with nut
B) Washer
C) Elbow
FO 0814
FO 0264
Installation
Important
This appliance must be installed by qualified
personnel.
The installer shall verify the satisfactory operation
of the ignition system on all burners both
individually and in combination.
The manufacturer will not accept liability, should
the above instructions or any of the other safety
instructions incorporated in this book be ignored.
Regulations
This appliance shall be installed in accordance with the
manufacturers installation instructions, local gas fitting
regulations, municipal building codes, AS5601 (AG601)
and any other relevant statutory regulations.
Data label
The data label is located on the bottom of the hob. This
appliance is suitable for Natural or Universal LPG.
Ensure that the gas supply matches the data label. A
duplicate of the data label is supplied in the packaging
of the user manual and must be attached to readily
accessible adjacent surfaces of the appliances.
Connection to the gas supply
Gas connection must be carried out in conformity with
the regulations in force. The appliance leaves the
factory tested and regulated for the type of gas indicated
on the plate which is situated in the lower position near
the gas connection tube. Ascertain that the type of gas
with which the appliance will be supplied is the same
as that indicated on the plate.
If different carry out all the operations according to the
indications cited in the paragraph adaption to different
types of gas.
For a maximum output and minimum consumption
ascertain that the pressure of the gas used has the
values indicated in the table of burner characteristics.
The joint is mounted on the intake area of the pipe,
fitted with a filleted nut G 1/2", between the sealing
components. Screw the parts without forcing, turn the
joint in the direction required and then tighten
everything.
Connection
Carry out the connection to the gas plant only by
means of a rigid metallic pipe conforming to the
regulations in force.
This appliance is not suitable for connection with a hose
assembly.
The joint for the entry of gas into the appliance is
threaded R 1/2" (male thread).
Carry out the connection avoiding any type of stress
on the appliance.
It is important to install the elbow correctly, with
the shoulder on the end of the thread, fitted to
the hob connecting pipe. Failure to ensure the
correct assembly will cause leakage of gas.
Natural gas appliances must be fitted with a pressure
regulator and be installed at the inlet connection. The
gas pressure must then be set as a part of the
commissioning procedures.
For U-LPG the pressure adjustment is made via the
regulator fitted at the domestic cylinder. The natural
gas regulator and U-LPG pressure test point must be
accessible with the appliance installed.
Important
Upon completion of installation, always check:
that all the joints are completely sealed by using a
soapy solution, never a flame;
that the gas pressure has been regulated to 1.00kPa
for Natural Gas and 2.75kPa for Universal-LPG. The
pressure test point is located on the regulator. The
pressure should be measured and adjusted with the
Wok burner on high flame;
that the automatic ignition system is operating
satisfactory on all burners, both individually and in
combination;
that the burners operate correctly, are stable, without
yellow tipping or excessive noise on high and low
flame.
Then demonstrate to the customer the appliance
operation and leave these instructions.