Over-the-Range Microwave
EI30SM35Q
29
7
/8"
15
1
/32"
rear
extrusion
lower
extrusion
Power cord
location
Blower plate allows for vertical
or horizontal ducting
Allow at least 26" clearance
for door depth when open
16
13
/32"
Backsplash
12"
min.
13"
max.
2"
min.
Rear Wall
16
1
/2"
min.
30"
min.
66"
min.
from floor
to top of
microwave
Bottom edge of
cabinet MUST be
30"
min. from
cooking surface
Cabinet MUST be
capable of
supporting a total
load of 150 lbs.
30"
min.
Microwave MUST
be mounted to
BOTH a top cabinet
AND a wall*
Locate 120V/60Hz grounded outlet inside upper cabinet
30" Over-the-Range Microwave Specifications
Product Weight – 64 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 1.6 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for safe
operation.)
Amps @ 120 Volts = 15 Amps
Always consult local and national electric codes.
Grounded outlet should be located in cabinet above, with hole in base to
route power cord. Carefully follow top template instructions for power cord
clearance when installing beneath smooth, flat cabinets.
Microwave’s ventilation system is preset to recirculate air inside with no
ducting system required. Exhausting air outside is optional, using either
vertical or horizontal ducting system. (Refer to Ducted Option Specifications
for outside ventilation.)
For safe and proper installation, microwave MUST be mounted to BOTH
a top cabinet AND a wall, and connected to at least one wall stud. Can NOT
be installed in island or peninsula cabinet arrangements.
Cabinet bottom MUST be level to insure proper installation.
Cabinet MUST be capable of supporting a total load of 150 lbs.
Filler blocks recommended for installation when cabinet front hangs below
recessed bottom shelf.
Minimum distance of 30" required from cooking surface to bottom edge
of top cabinet.
Minimum distance of 66" required from floor to top of microwave.
Opening between cabinets MUST be 30" wide and free of obstructions.
For openings up to 36" wide, order optional 36" Filler Kit to fill in gap
between unit and cabinets.
Allow 26" minimum clearance for 90° door swing.
Ducted Option Specifications
For outside ventilation.
Exhaust duct adapter will be needed for outside ventilation, to mate with
standard 3-1/4" x 10" rectangular duct. If round duct required, rectangular-
to-round transition adapter will be needed with no more than 6" diameter.
For most efficient airflow exhaust, use a straight run or as few elbows
as possible with a maximum duct length of 3-1/4" x 10" rectangular or
6" diameter round duct, not to exceed 120 equivalent feet.
For horizontal installation, be sure to allow enough space between wall
studs to accommodate exhaust.
Refer to installation instructions on web for detailed duct preparation and
converting exhaust vent blower system for exterior exhaust ventilation.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
36" Filler Kit: S – (PN # MWFILKTSS).
OVER-THE-RANGE MICROWAVE
EI30SM35QS