Service manual

EElleeccttrroonniicc CCoonnttrrooll
3-20
TTeesstt AAccttiivvaatteedd CCoommppoonneenntt
Lights / Buttons test
Motor Counter-Clockwise
(CCW)
Contact Sensor
Motor Clockwise (CW)
Motor CW
Error code history display
Software version
Lights / Buttons test
DDiiaaggnnoossttiicc MMooddee
TToo SSttaarrtt tthhee DDiiaaggnnoossttiicc MMooddee
1. Press the “CANCEL” button to enter standby mode and enable diagnostic entry.
2. Within 10 seconds after pressing “CANCEL”, press any button to wake up the control.
3. Within 5 seconds of wake up, turn the selector knob to the far left cycle and press and hold the
“CANCEL” and the far left button under the display simultaneously for 3 seconds to enter the
Diagnostic Mode.
NNOOTTEE::
To save time at wake up, the welcome screen can be bypassed by turning the selector knob.
4. Upon entering Diagnostic Mode, all lights should flash for IQ Touch™ models and all lights on for the
Wave Touch™ models.
5. The following steps can be cycled through by turning the selector knob clockwise:
SSeelleeccttoorr
PPoossiittiioonn
0
1
2
3
4
5
6
7
8
9
10
11
EElleeccttrriicc
Lights/Buttons
test + Motor
CW
Motor CW +
Heater
1
Motor CW +
Heater
1 + Heater 2
Motor CW +
Heater1 +
Heater 2 +
Heater 3
GGaass
Lights / Buttons
test + Motor
CW + igniter
Motor CW +
Heater
Motor CW +
Heater
Motor CW +
Heater
OOppeerraattoorr CChheecckk
Check Motor function. Look for Drum
rotation in counter-clockwise direction.
Check moisture reading. Place fingers
across Contact Sensor and look for digit
display to change from “1111” to “8888”
Check Motor function. Look for Drum
rotation in clockwise direction.
Check all buttons and lights. Press all
buttons and check for beep and button
ID number in digit display. Check to see
that all Lights function
Check Motor and Heater function. Check
Outlet Control Thermistor value in digit
display.
Check Motor and Heater function. Check
Inlet Control Thermistor value in digit dis-
play.
Check Motor and Heater function. Check
Outlet Control Thermistor value in digit
display.
Check for Mist
Check last 5 error codes displayed
(See Error Code Table )
Software version
LLCCDD rrooww
“MOTOR
CCW”
“MOIST.
BARS”
“MOTOR
CW”
“HEAT1 -
NTC1”
“HEAT2 -
NTC2”
“HEAT3 -
NTC1”
“MIST
VALVE”
Software
version
LLCCDD ddiiggiittss
“1111” if Contact
Sensor open circuit;
”8888" if Contact
Sensor short circuited
Button id number
Outlet Control
Thermistor value
(degrees F)
Inlet Control
Thermistor value
(degrees F)
Outlet Control
Thermistor
value (degrees F)
error code
Software
version
Diagnostic Mode