Errata corrige REFRESHMENT CENTER Built-In appliance
errata corrige electrolux 3 Package content The package contains the mentioned material with the addition of: - 10 screws 3.5x16 and 3 screws M4x8 - user instruction manual Installation Cabinet dimensions 50 50 1.The required dimensions of the cabinet space for the positioning of the unit are: 1. Height (1): 380mm 2. Depth (2): 560mm 3.
electrolux errata corrige Filter cartridge first installation Lift the drip tray and pull upward the locking spring of the Refreshment center util it unblocks (Fig.8) Fig. 8 Pull the bottom edge of the unit and extract the Refreshment Center (Fig.9). After pulling out the unit it is easier to access the left side, that contains the filter cartridge. Fig. 9 Remove the capsule. Connect the filter cartridge to the filter head turning it counter-clockwise (Fig.10) Fig. 10 Check for water leaks.
errata corrige electrolux 5 CO2 bottle first installation Disposable Bottle The CO2 bottle can be found on the left side of the unit. Remove the green cap and screw the pressure reducer onto the bottle until fully tightened (Fig.11). Open the valve on the reducer until it reaches a pressure of about 3 bar (Fig.12). In order to obtain a higher level of CO2 concentration, it is possible to increase the pressure up to a maximum of about 4 bar. Fig.
electrolux errata corrige Alarms Led indications Filter red led blinks slowly Filter red led is on Filter red led stays lit Carbonated water led blinks slowly CO2 bottle led stays lit Meaning Filter is about to exhaust. 2,700 liters of water have been dispensed. Please replace the filter cartridge as described in the paragraph "Filter replacement" Filter exhausted. 2,800 liters of water have been dispensed.
errata corrige electrolux 7 Led indications Meaning - Ambient water - cold water - carbonated water leds blink Volumetric turbine malfunctioning. The two possible causes simultaneously are: and fast 1. Lack of water supply from the water main; 2. Low pressure in the water inlet. Please check the presence of water supply to the unit. Turn unit off and then back on using the on/off switch on the front panel.
electrolux errata corrige Ice melting Do not block ice exit with any object, since it may damage the unit or prevent the correct closing of the exit. This would cause a rise in the internal temperature with subsequent rapid ice melting CO2 bottle replacement (for food) When CO2 led turns on, please replace the old bottle with a new one as described below: 1. unblock the locking spring from under the drip tray (Fig. 8).
errata corrige electrolux 9 Sanification + filter cartridge replacement if few days after the installation the filter replacement led turns on, please activate the sanitation procedure to restore all functions. In such case, filter replacement is not necessary When the “filter” led turns on, it is necessary to replace the cartridge filter as described below: 1. unblock the locking spring (Fig.8) and pull out the Refreshment Center unit (Fig.15); 2. turn off the unit through the main on/off switch; 3.
electrolux errata corrige 9. turn off the unit through the main switch; 10. remove the sanification cartridge (Fig.19) and connect the new filter cartridge to the head as shown on filter cartridge instructions (Fig.20); 11. turn on the main switch and push the Refreshment Center into the cabinet until the locking spring clicks (Fig.21); 12. wait 4 minutes before activating the unit pushing the on/off button on the control panel; 13.
errata corrige electrolux 11
electrolux errata corrige Subject to change without notice