This cooker must be earthed.
The manufacturer declines any liability
should these safety measures not be
observed.
This cooker is designed to be connected to
a 230/400V, 50Hz AC electrical supply.
Before switching on, make sure the
electricity supply voltage is the same as that
indicated on the rating plate.
Note:
In case of a direct connection to the mains
you have to interpose an omnipolar switch
with a minimum opening between contacts
of 3 mm must be done under over voltage
category III condition.
The switch should be sited within 2m of the
hob and be easily accessible upon
completion of the installation.
The yellow-green grounding cable has not to
be interrupted by the switch.
NOTE: The earth wire should be about 10-
12 cm longer than the live and neutral wires.
To use cable type H05 RR-F with the
section indicated in the table no.1.
Important
Ensure that the supply cord is not in
contact with any part of the hatched
area shown in the diagram.
If the supply cord is damaged it must
be replaced by the manufacturer or its
service agent or a similarly qualified
person in order to avoid a hazard.
Before connecting check that:
fuse and household electric installation
can bear the charge of the appliance
(see rating plate);
The socket or the omnipolar switch used
for connection is easily reachable when
the appliance is installed.
How to proceed?
Unscrew and remove the protective
cover at the back of the appliance;
Connect the power cord to the terminal
of the cooker according to the table
no.1;
Fix by means of cable clamp;
Make sure that the connection to the
terminal is matching the network power;
Remount and screw the protective cover at
the back of the appliance
Table no. 1
Nominal tension 230V ~/400V 3N/ 230V 3~/400V 2N~
Connection type Single phase Tri-phase
Tri-phase Y 3
ph. + neutral
Tri-phase Y 2
ph. + neutral
Cable connection
to the terminal
plate
1 2 3 4 5
L1
N
L3
5
1 2
3 4
L1 L2
3
1
L3 L1
4 5
N
L2
2
4 5
N
2 3
L2 L1
1