User manual

BURNER NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Semi-rapid 2.0 0.45 96
Auxiliary 1.0 0.35 70
Oven 2.25 1.0 108
Grill 2.0 1.5 108
17.6 Gas burners for LPG G30 28-30 mbar
BURNER NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Rapid 3.0 0.72 88
Semi-rapid 2.0 0.43 71
Auxiliary 1.0 0.35 50
Oven 2.25 1.0 71
Grill 2.0 1.5 71
17.7 Gas connection
The gas pipe in the appliance has two
endings. You can connect the gas supply
to either one of them. The pipe that is not
used must be clogged with the pipe
closer, which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with
the regulation in force. If you use flexible
metallic pipes, make sure they do not
come in touch with mobile parts and they
are not squeezed.
17.8 Flexible nonmetal pipes
connection
If you have an easy access to the
connection, you can use a flexible pipe.
The flexible pipe must be tightly attached
by clamps.
In installation always use the pipe holder
and the gasket. The flexible pipe can be
applied when:
it can not get hotter than room
temperature, higher than 30 °C,
it is not longer than 1500 mm,
it has no narrowing anywhere,
it is not twisted or tighten,
it does not get in touch with sharp
edges or corners,
it's conditions can be easily checked.
When checking the flexible pipe make
sure:
it does not show cracks, cuts, marks
of burnings on the two ends and on its
full length,
the material is not hardened, but
shows its correct elasticity,
the fastening clamps are not rusted,
expired term is not due.
ENGLISH 25