User manual

tween each unit and the sides of the appli-
ance.
The levelling feet fitted to the appliance will
achieve a nominal height to hotplate of
907mm + / - 5mm.
Fig 1.a Fig 1.b
L.P.G. cookers MUST NOT be installed
below ground level i.e. in a basement or
aboard any boat, yacht or other vessel.
Levelling the appliance
Adjustment to suit floor conditions or height
is obtained by rotating clockwise or anti
clockwise the feet at the front and rear of the
appliance.
A spirit level should be placed on one of the
shelves to confirm the appliance is correctly
levelled.
Connecting to the electricity supply
Warning! This appliance must be
earthed. Do not earth this appliance to
the gas supply piping. Connect to 230 -
240V AC supply only.
The electrical connection should be made
using a double pole isolating switch (cook-
er socket) with at least 3mm contact sep-
aration in all poles. The cable must have
conductors of sufficiently high cross-sec-
tional area to prevent overheating and de-
terioration.
We recommend you use a new length of
6mm
2
twin core and earthed cable to en-
sure your safety.
Make connection as shown.
ENSURE THAT THE LINKS ARE
FITTED AS SHOWN
L
L
N
N
N
Blanking plates not to be removed
Proceed as follows :-
Preform wires to the appropriate shape
to suit fitting into the mains terminal
block.
Strip inner insulation on wires using wire
strippers.
Twist the bared wires using pliers.
Cut bared wires 10mm away from the
end of the inner insulation. Where unin-
sulated Earth wires are used ensure they
are suitably sheathed to leave 10mm
bare wire to fit into the terminal.
Clamp bare wires into the relevant ter-
minal and check they are held by tug-
ging each one in turn.
Ensure all screws are securely tight-
ened.
Clamp the mains cable securely ensur-
ing 5mm of the outer insuation is inside
the terminal block and that the wires are
not taut but not so slack as to cause any
fouling.
Connect the remaining end of the mains
cable to the appliance to the appliance
point / junction box.
Place fuse / miniature circuit breaker in
circuit and switch on at mains.
HOUSE CIRCUIT
Earth leakage / continuity tests must be
carried out before the appliance is con-
nected to the mains supply and re-
checked after fitting.
Connecting to the gas supply
This appliance is designed to be installed
with an appliance flexible connection only.
Supply piping should not be less than R3/8.
Connection is made to the Rc ½ (½” B.S.P.)
female threaded entry pipe located just be-
low the hotplate level on the rear left hand
side of the appliance.
22 electrolux