INSTRUCTIONS MANUAL SPLIT TYPE ROOM AIR CONDITIONER MODELS: EAS(C,E)09C2ASK(W,S,M) / EAS(C,E)12C2ASK(W,S,M) EAS(C,E)18C2ASK(W,S,M) / EAS(C,E)24C2ASK(W,S,M) EAS(C,E)09P5ASK(W,S,M) / EAS(C,E)12P5ASK(W,S,M) EAS(C,E)18P5ASK(W,S,M) / EAS(C,E)24P5ASK(W,S,M) 110823P S(351-358)EM_ENGLISH Please read this manual completely before operating your room air conditioner.
contents electrolux 02 01 electrolux welcome Welcome to the world of simple handling and no worries. Contents Thank you for choosing Electrolux. This manual contains all of the information required to guarantee your safety and the appropriate use of your air conditioner. 01. 02. 03. 04. 05. Please read all of the instructions before using the air conditioner and keep this manual for future reference. We know you will enjoy your new air conditioner and thank you for choosing our product.
03 electrolux contents safety precautions electrolux 04 Safety precautions 6.7 How the air conditioner works.............................................................40 - Automatic operation - Cool/Heat and Fan only operation - Dry operation - Air flow direction adjustment - Sleep mode - Timer - Cancel timer operation - Optimal operation 6.8 How to use the indoor unit...................................................................
safety precautions electrolux 06 05 electrolux safety precautions conditioner. It contains contaminants and could make you sick. 10.Do not use the power cord close to heating appliances. It may cause fire and electric shock. 11.Do not damage or use an unspecified power cord. It may cause electric shock or fire. 12.Do not direct airflow at room occupants only. This could damage your health. 13.Always install circuit breaker and a dedicated power circuit. No installation may cause fire and electric shock.
choosing the installation site electrolux 08 07 electrolux safety precautions Choosing the installation site there is concern of damage due to falling of unit. 28.Always insert the filters securely. Clean filter once every two weeks. Operation without filters may cause failure. 29.Do not place heavy object on the power cord and take care so that the cord is not compressed. There is danger of fire or electric shock. 30.Do not place obstacles around airinlets or inside of air-outlet.
parts list electrolux 10 09 electrolux outdoor unit Parts list Outdoor Unit 1. The outdoor unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated. More than 30cm More than 60cm More than 30cm 2. The site must support the weight of the outdoor unit and allow for vertical installation. 3. There must not be the possibility of increased noise and vibration at the site. 4.
indoor unit installation electrolux 12 11 electrolux parts list Indoor unit installation Installation plate description 1 More than 15cm 2 3 above 150mm from Installation plate the ceiling Indoor unit outline Indoor unit More than 12cm above 120mm from the wall 90 40 40 45 6 B above 120mm from the wall Refrigerant pipe hole (left) Ø 65 A More than 12cm Refrigerant pipe hole (right) Ø 65 Models < 12000 Btu’s (A: 710, B: 250) Model 12000 Btu’s (A: 790, B: 265) Air filter 6 More than 60c
indoor unit installation electrolux 14 13 electrolux indoor unit installation 150mm del techo Connective pipe and drainage installation 998 119 Drainage above 120mm from the wall 1. Run the drain hose sloping downward. Do not install the drain hose as illustrated below. Indoor unit outline Modelos 24000 Btu’s Fixing the installation plate Connective pipe installation 1.
outdoor unit installation electrolux 16 15 electrolux indoor unit installation Outdoor unit installation 3. Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall. Get it out after finish piping. 4. Push the lower part of the indoor unit up on the wall, then move the indoor unit from side to side, up and down to check if it is hooked securely. Piping and wrapping 1.
refrigerant pipe connection electrolux 18 17 electrolux outdoor unit installation Refrigerant pipe connection A Settlement of outdoor unit Anchor the outdoor unit with a bolt and nut 10 or 8 tightly and horizontally on a concrete or rigid mount. Flaring work Air inlet B Main cause for refrigerant leakage is due to defect in the flaring work.
electrical work electrolux 20 19 electrolux refrigerant pipe connection Electrical work Electric safety regulations for the initial Installation 4. Flaring work A) Firmly hold copper pipe in a die in the dimension shown in the table below. OUTER DIAMETER (mm) Bar Copper pipe Handle A (mm) Máx. Mín. 6,35 1,3 0,7 9,53 1,6 1,0 12,70 1,8 1,0 16 2,4 2,2 Connection Adjustment 1. Align the pipes to be connected. 2.
electrical work electrolux 22 21 electrolux electrical work Connect the cable to the indoor unit 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord, type designation H07RN-F or heavier cord. 3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw. 4. Ensure the colour of wires of outdoor unit and the terminal Nos.
electrical work electrolux 24 23 electrolux electrical work Connect the cable to the outdoor unit 1. Remove the electrical control board cover from the outdoor unit by loosening the screw. 2. Connect the cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units. 3. To prevent the ingress of water, from a loop of the connective cable as illustrated in the installation diagram of indoor and outdoor units. 4.
electrical work electrolux 26 25 electrolux electrical work Caution After the confirmation of the above conditions, prepare the wiring as follows: 1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2.
electrical safety electrolux 28 27 electrolux electrical work Electrical safety Perform the electric safe check after completing installation: When using the vacuum pump For method of using a manifold valve, refer to its operation manual. 1. Completely tighten the flare nuts, A, B, C, D, connect the manifold valve charge hose to a charge port of the low-pressure valve on the gas pipe side. 2. Connect the charge hose connection to the vacuum pump. 3. Fully open the handle Lo of the manifold valve. 4.
29 electrolux operation test preparing the device for operation electrolux 30 Operation test Preparing the device for operation Perform test operation after completing gas leak check at the flare nut connections and electrical safety check. 1. Contact a specialist to install the device. 2. Guarantee that the unit is appropriately fastened and complies with all of the aforementioned safety norms. 3. Before operating the air conditioner, ensure that the air filter is installed correctly. 4.
product description electrolux 32 31 electrolux product description Product description Display panel (indoor unit) 1 Front panel frame 2 Front panel 13 DEFROST*: Displayed when the 3 Air filter 4 5 6 7 8 9 air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation.
remote control electrolux 34 33 electrolux remote control Remote control Remote control operation When should the batteries be replaced 1. When there is not a “beep” anymore from the indoor unit when using the control remote or the signal light indicator does not lit. 2. The indoor unit does not respond to the remote control commands to activate the programs. 1. Operation mode: Cool, Heat (Only for the models with cool/heat), DRY, FAN, and AUTO (Automatic). 2. Timer 24 hrs. 3.
remote control description electrolux 36 35 electrolux remote control description Remote control description 1 ON/OFF: Push this button to start operation, push the button again to stop operation. 2 MODE: Each time you push the button, a mode is selected in a sequence that goes from AUTO, COOL*, DRY, HEAT and FAN, as the following figure indicates: AUTO COOL DRY HEAT* FAN * Note: Only for heating and cooling models. 3 SWING: Push this button, the louver would swing up and down automatically.
lcd display indicators electrolux 38 37 electrolux remote control description LCD display indicators 11 CANCEL: Push this button to cancel the TIMER ON/OFF settings. 12 TURBO*: Push this button on COOL mode, the air conditioner goes into powerful cooling operation. Push again to cancel the TURBO function. *Note: Only for some models. 13 LED: Press this button to clear the digit display in the air conditioner, press it again to activate it. 14 CLOCK: Use to set the time.
39 electrolux clock adjustment how the air conditioner works electrolux 40 Clock adjustment How the air conditioner works Before you start operating the air conditioner, set the clock of the remote controller using the procedures given in this section. The clock panel on the remote controller will display the time regardless of whether the air conditioner is in use or not.
how the air conditioner works electrolux 42 41 electrolux how the air conditioner works SLEEP mode Press the sleep button to activate the sleep mode. To deactivate, press the button again. Cool only mode: Time Set temperature DRY Function 1 °C Set temperature • After and hour of operation, the adjusted temperature will increase 1º C. After, the unit keeps operating 2ºC above the adjusted temperature. 1 hour 1 hour SLEEP FUNCTION (Cooling mode) • The indoor unit fan operates at a low velocity.
how to use the indoor unit electrolux 44 43 electrolux how the air conditioner works How to use the indoor unit seconds after, the adjusted temperature will be displayed. 5. The time of on and off in the air conditioner is has been set. Canceling Cancel button (CANCEL) Press the CANCEL button to cancel the timer setting. When you select the timer operation, the remote controller automatically transmits the timer signal to the indoor unit at the specified time.
45 electrolux how to use the indoor unit manual operation (without remote control) electrolux 46 Manual operation (without remote control) Press the SWING button on the remote controller. To stop the function, press the SWING button again. Press AIR DIRECTION button to lock louver in desired position. The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in operation (including when the TIMER ON is set).
maintenance electrolux 48 47 electrolux maintenance Maintenance then dry. 6. Clean the support frame using a vacuum cleaner or water. After, dry for a couple of hours or until dry. 7. Insert the fresh air filter in its original place. 8. Insert the high part of the air filter (fresh air filter + Support frame) again in the unit keeping in mind that the outside border (right and left) are lined up correctly, now place the whole filter in the initial position.
49 electrolux operation tips operation tips electrolux 50 Operation tips The following events may occur during normal operation. Protection of the air conditioner. Compressor protection The compressor can't restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached. 1. When heating has just starting. 2.
technical specifications electrolux 52 51 electrolux solutions for problems Solutions for problems Technical specifications If your air conditioner malfunctions, check the following information to find solutions or probable causes of the failure. Do not try to repair the unit by yourself, if these solutions do not solve the failures; call your local service repair team. COOL MODELS Poor Equipment performance 1. The air outlet or inlet in the exterior part is obstructed. 2.
notes electrolux 54 53 electrolux technical specifications NOTES HEAT & COOL MODELS OUTDOOR UNIT EASC09P5ASK* EASC12P5ASK* EASC18P5ASK* EASC24P5ASK* INDOOR UNIT EASE09P5ASK* EASE12P5ASK* EASE18P5ASK* EASE24P5ASK* *Color (W=White;S=Silver;M=Mirror) Cycle W,S,M W,S,M W,S,M W,S,M Heat & Cool Heat & Cool Heat & Cool Heat & Cool Cooling power (Btu/h) 9000 12000 18000 24000 Heating power (Btu/h) 9000 12000 18000 24000 Rated voltage (V) 220 220 220 220 Frequency (Hz) 50 50 5