User's Manual

Installation electrolux 11
EN
Connection in Ducting Version
When installing the ducting version,
connect the hood to the chimney using
either a fl exible or rigid pipe ø 150 or
120 mm, the choice of which is left to
the installer.
To install a ø 120 mm air exhaust con-
nection, insert the reducer fl ange 9 on
the hood body outlet.
Fix the pipe using the pipe clamps 25
provided.
Remove charcoal fi lters, if present.
Connection in Recycling Version
Fix the connection 15 to the frame
using the 4 screws provided.
Fix the fl ange 10 to the lower opening
of the connection 15.
Connect the hood air outlet to the
ange in the lower part of the junction
using a rigid or fl exible ø 150 tube (by
installer’s choice).
Ensure that the charcoal fi lters have
been tted.
Chimney assembly / Mounting
the hood body
Position the upper chimney section
and fi x the upper part to the frame
using the 2 screws 12c (2,9 x 6,5)
provided.
Similarly, position the lower chimney
section and fi x the lower part to the
frame using the 2 screws 12c (2,9 x
6,5) provided.
Before fi xing the hood body to the fra-
me:
Remove the grease fi lters from the
hood body.
Remove charcoal fi lters, if present.
From below, use the 4 screws 12f
(M6 x 10)provided to fi x the hood
body to the frame.
9
ø 150
ø 120
25
25
15
10
12c
12c
12f
1