12 electrolux Installation / Use
EN
Electrical Connection
Connect the hood to the mains
through a two-pole switch having a
contact gap of at least 3 mm.
Remove the grease fi lters (see para-
graph Maintenance) being sure that
the connector of the feeding cable is
correctly inserted in the socket placed
on the side of the fan.
Connect the control connector Cmd.
Connect the lights connector Lux.
Place the connectors in the junction
box 24 and close it using the 2 screws
12e (2,9 x 9,5) provided.
Fix the junction box to the hood body
using the 2 screws 12c (2,9 x 6,5)
provided.
For the recirculation version, fi t the
activated carbon odour fi lter.
Replace the grease fi lters.
USE
The hood can be switched on pushing
directly onto the requested speed
without fi rstly having to select 0/1 but-
ton
L T1 T2 T3 T4 T5 F
24
12e
Cmd
12c
Lux