Technical data

Electrics
Cascade/Pump Indicators
This module provides indicators for the
Cascade water heater fitted in your caravan.
The three indicators show the following:
Green LED - Heater is switched on
Red LED - There has been a heater
fault, probably a low gas
supply
Yellow LED - DC voltage supply is too low
for the heater to operate
Also included in this module is a pump
running indicator. This red indicator will light
up as a warning when the water pump has
been activated.
SWITCH MODULE
This module contains all the control switches
for electrical facilities within the caravan.
12V Isolation Switch
This switch will effectively isolate 12 volt
power to all dc circuits by opening a relay.
This switch should be used only when
wishing to isolate power for reasonably short
periods (e.g. when going out for the day).
For isolation during storage the Car/Van
switch on the ESM2000 unit should be used
(place Car/Van switch to the centre 'off'
position).
Pump switch
This switch merely energises the inboard
water pump ready for use. In caravans with
an outboard pump, this switch will be a two
way type for energising whichever pump is
required (i.e. internal or external)
Entry Light switch
This switch energises an internal entry light
Battery/Water test switch
(KT9/2000GT only)
This switch should be pressed to the battery
position to test battery voltage or the water
position to test the water remaining in the
inboard tank.
Water Heater switch
This switch energises the gas ignition on the
Carver water heater. When switched to the
'on' position, the green indicator marked
'heater on' should illuminate and the ignition
should energise.
ALARM MODULE - IDM 2000
Important
This handbook should be read through
carefully before any attempt is made to
install and use the system. For case of
understanding it is suggested that this
handbook is read whilst viewing the keypad.
Your alarm system, when new, contains the
manufacturers code 1234. For security
reasons this should be changed as soon as
practical. (See 'Changing the Personal
Code').
Factory Settings
Entry Delay - 0:00 (0 secs)
Exit Delay - 0:20 (20 secs)
Siren On Time - 1:00 (1 minute)
Manufacturers
Personal Code - 1234
Changing the Personal Code
1. Press "F", press "1"
2. Enter the current code. (1234 if new).
3. Enter desired 4 digit code.
4. Press "F".
5. This operation can be cancelled at any
time before step 4 by pressing "C".
Changing the Entry Delay Time
1. Press "F", press "0".
2. Enter your personal code.
3. Enter the new entry delay as 3 digits, i.e.
10 seconds is entered 010.
4. Press "F".
5. This operation can be cancelled at any
time before step 3 by pressing "C".
Note: The Entry Delay Time must be as
short as possible to prevent compromising
security.
42