Technical data

Fitted Equipment
PROGRAMMABLE HEATING
TIMER (USER INSTRUCTIONS)
(Fig.1)
Features: -
7 Day / 24 Hour Programmable Timing
12V DC Operation
Manual and Timed Override Option
USER INSTRUCTIONS
Setting the Clock: -
1. Move the Function Select Slider Switch
into the top "Clock set / Clock Adjust"
position indicated by a Clock Face symbol.
2. Set the day by pressing the
corresponding day button M = Monday,
T = Tuesday, etc.
3. Set the time by using the + and - arrow
keys to increase or decrease the time
shown until the correct time is reached
(Holding the + and - keys in will Scroll
quickly to the desired time)
Programming the Heating Timer: -
1. Move the Red slider switch to the
Position Marked "PROG" (Program).
2. Using the + and - Arrow Keys set the first
Program time, the ON time (note - ON is
shown in the top right corner of the
display)
3. Set the Day or Days this switching time
should be active, using the Day Select
buttons.
(
Note - an active day will appear as mark
at the bottom of the display
corresponding to a day select button.)
4. Press the Enter Key to store this
information. After pressing the Enter key
the display will change, ready to set the
next time. OFF or ON will be shown in the
top right corner indicating which time is
next.
5. The next switching time can now be
programmed by repeating steps 2, 3
and 4.
6. Run the programmed switching sequence
by moving the Function Select Slider to
the "Auto" position. The module will now
carry out the switching operations as
programmed, displaying the current time
along with the state of the switch i.e. ON
or OFF.
Note - the Time display will not be seen if
12V DC is not present.
Timed / Manual Override.
This function gives the ability to Manually
override the Timer switch Program turning
the Heating system ON or OFF, and also
allows the user to set this override to last for
a timed period (set in hours)
Manual Override: -
1. Move the Function select slider down to
the "Timed / Manual Override" position.
The display will read - h with ON or OFF
to the Right (depending on the current
switch state).
2. Change the current switch state press the
"On / Off Switch Select" button the
display will change to read the new
switch state on the right side. This timer
will remain in this state until the Switch
Select Button is pressed again or the
Function select slider is returned to the
"Auto" position and a switching program
is run.
67