Technical Manual EMP 8x0.00/04/13 v5 wh Münzprüfer Dietmar Trenner GmbH, Germany Safety Precautions You are advised to observe the safety information during operation, maintenance and repairing of electronic coin selectors of the EMP 800 series. Failure to do so may result in warranty and other claims being excluded. Whilst every care has been taken in the preparation of information contained in this manual, wh Münzprüfer will not be liable for any consequential loss or damage howsoever caused.
wh Münzprüfer Dietmar Trenner GmbH, Germany Technical Manual EMP 8x0.00/04/13 v5 Table of Contents 1 1.1 1.2 2 Introduction ......................................................................................................................... 5 The EMP 8x0.00 v5, 8x0.04 v5 and 8x0.13 v5 series................................................... 5 Technical Data............................................................................................................... 7 1.2.1 The EMP 8x0.00 v5, 8x0.
Technical Manual EMP 8x0.00/04/13 v5 wh Münzprüfer Dietmar Trenner GmbH, Germany 4 The Label............................................................................................................................ 38 5 Maintenance ....................................................................................................................... 40 6 Connecting Diagrams .........................................................................................................
wh Münzprüfer Dietmar Trenner GmbH, Germany 1 1.1 Technical Manual EMP 8x0.00/04/13 v5 Introduction The EMP 8x0.00 v5, 8x0.04 v5 and 8x0.13 v5 series The electronic coin selectors EMP 8x0.00 v5, EMP 8x0.04 v5 and EMP 8x0.13 v5 are available in the following versions: with front plate: Standard front plate Mini front plate Stainless steel front plate (F 800) (F 810) (F 801) EMP 800.xx v5 EMP 890.xx v5 EMP 850.
Technical Manual EMP 8x0.00/04/13 v5 wh Münzprüfer Dietmar Trenner GmbH, Germany EMP 830.xx v5 EMP 840.xx v5 ! The second digit of the model number indicates the mechanical version and the two digits after the decimal point identify the electronic interface. connector for reject signal (EMP 800 and 890 only) blocking switches 9 to 16 cctalk connector 1 to 8 ST EMP (parallel) connector for external sorting flaps Page 6/42 SCI- / MDB connector (serial) Version 1.
wh Münzprüfer Dietmar Trenner GmbH, Germany 1.2 1.2.1 Technical Manual EMP 8x0.00/04/13 v5 Technical Data The EMP 8x0.00 v5, 8x0.04 v5 and 8x0.13 v5 Coin Selector Features The EMP 8x0.xx v5 is a 32 channel, 6-output line coin selector. Any coin may be assigned to any parallel output channel and the length of the output pulse signal may be set from 1 ms to 65 seconds. Only 5 output channels will be available if one of the output lines is used for an inventory impulse. The EMP 8x0.
Technical Manual EMP 8x0.00/04/13 v5 1.2.2 wh Münzprüfer Dietmar Trenner GmbH, Germany Technical Overview of the EMP 8x0.0000 v5, 8x0.04 v5 and 8x0.13 v5 coin acceptance 32 coin channels, 16 master and 16 slave channels coin blocking Complete blocking via the machine controller. In addition, any individual coin, or group of coins can also be blocked through DIP switches. The 16 switches can be freely assigned to each of the 32 coin channels. Each channel can be assigned two switches.
wh Münzprüfer Dietmar Trenner GmbH, Germany 2 2.1 Technical Manual EMP 8x0.00/04/13 v5 Function of the Coin Selector Introduction This chapter gives directions for preparing the EMP 800 v5 for programming. Please conform to all safety precautions before making changes to the unit. Please note that all setting / programming of our electronic coin selectors may be carried out at the factory or by any authorised "wh Münzprüfer Service Centre.
Technical Manual EMP 8x0.00/04/13 v5 wh Münzprüfer Dietmar Trenner GmbH, Germany controller on 1 2 3 4 5 6 7 8 on 1 2 3 4 5 6 7 8 EMP 800 power Figure 2 Connection between a coin operated machine (controller), an installed coin selector and a PC ! Every coin selector is fully tested and configured at the factory and is supplied ready for installation. Please store the factory settings on the hard disk before making changes.
wh Münzprüfer Dietmar Trenner GmbH, Germany 2.2 Technical Manual EMP 8x0.00/04/13 v5 Programming of Coins There are a variety of ways in which the coin acceptance of the EMP 800 v5 may be programmed. The coin selector can “learn” new coin parameters, including individual tolerance requirements, with the help of the Calibration Function. Calibration is carried out either using the PC based wheasy 3 software or directly in the vending machine using the Teach mode Function (see On site programming).
Technical Manual EMP 8x0.00/04/13 v5 wh Münzprüfer Dietmar Trenner GmbH, Germany Figure 4 Calibration window for EMP 800 v5 coin selector The calibration mode “fix” is intended for use with coins and coin channels for which preset tolerance parameters are available and calibration mode “fix” is also preset. As a general rule, “fix” provides the best results when such information is already available.
wh Münzprüfer Dietmar Trenner GmbH, Germany Technical Manual EMP 8x0.00/04/13 v5 Channels 7 and 8 cannot be calibrated with the teach mode because the DIP switches 7 and 8 are used to set the acceptance tolerance and to activate teach mode respectively. ! Only 15 blocking switches are available on those coin selectors that have been factory set with the teach mode. The coin selector will not accept any coins while it is in the teach mode.
Technical Manual EMP 8x0.00/04/13 v5 wh Münzprüfer Dietmar Trenner GmbH, Germany successful when using „broad“ tolerances (blocking switch no. 7 OFF), teaching could be still possible using the narrow tolerances. 10. The teach mode is deactivated via blocking switch no. 8 (OFF). When the teach mode is deactivated, all blocking switches may then be used for individual coin blocking with the exception of blocking switch no. 8. 2.2.
wh Münzprüfer Dietmar Trenner GmbH, Germany Technical Manual EMP 8x0.00/04/13 v5 other coins. With selective cloning all coin channels with activated coin boxes will be cloned. The actual cloning process takes about 15 seconds after the OK button has been pressed. 2.3 Coin Selector Output Signals There are 6 open collector parallel outputs (current sink) on the EMP 800 v5 10-pin connector. They can be freely assigned in any combination to the 16 master channels.
Technical Manual EMP 8x0.00/04/13 v5 wh Münzprüfer Dietmar Trenner GmbH, Germany The signal is, however, of a very short duration relative to the normal acceptance output signal (credit pulse). This preceding coin output signal pulses before the coin selector magnet is activated. The signal has a maximum width of 10 ms if the coin selector is blocked (from accepting coins) via the general blocking input.
wh Münzprüfer Dietmar Trenner GmbH, Germany Technical Manual EMP 8x0.00/04/13 v5 Figure 8 shows the acceptance of the coin after it has been identified. The sequence of events is as follows: 2.3.4.1 - The preceding signal starts on the assigned output line after the coin has been identified. - The machine controller removes the general blocking signal after 3 ms. Almost immediately, the coin selector ends the preceding signal and energizes the acceptance magnet.
Technical Manual EMP 8x0.00/04/13 v5 2.3.6 wh Münzprüfer Dietmar Trenner GmbH, Germany Parallel Output Connector (ST EMP) The parallel output connector is a 10-pin, dual row .1-inch center jack as specified by DIN 41651. The connector has the following pin out: Pin No. 1 2 3 4 5 6 7 8 9 10 2.
wh Münzprüfer Dietmar Trenner GmbH, Germany Technical Manual EMP 8x0.00/04/13 v5 In certain circumstances, the general blocking signal can also be used to block individual coins (chapter 2.3.4 preceding coin output signal – Option /S). 2.4.2 Individual Coin Blocking via DIP switches The coin selector has 16 DIP switches for individual coin blocking. Blocking is not active, that is, the coin will be accepted when the switch is in the “OFF” position. A coin will be rejected when the switch is “ON”.
Technical Manual EMP 8x0.00/04/13 v5 Figure 10 wh Münzprüfer Dietmar Trenner GmbH, Germany Window for “Coin Values” The individual fields are defined as follows: • S.Value (Calculated Coin value) The calculated coin value is stored in the coin selector. This value uses the machine controller for the determination of credit and the selector for calculating the number of inventory pulses. • Value (Actual coin value) This “value” is not stored in the coin selector.
wh Münzprüfer Dietmar Trenner GmbH, Germany Technical Manual EMP 8x0.00/04/13 v5 There are some special fields at the bottom of the window, below the heading of “Scaling.” These adjustable parameters have the following meaning: 2.6 • Scaling Factor This value is used in vending machines that communicate with the coin selector over the serial MDB protocol. The vending machine may read these values during a status request.
Technical Manual EMP 8x0.00/04/13 v5 2.7 wh Münzprüfer Dietmar Trenner GmbH, Germany Control for External Sorting Flaps The 2- or 3-way sorter SRT 800 is available for the EMP 800 v5. The coin selector can also be used in combination with many other sorter available on the market. 2.7.1 Option /X The EMP 800 v5 incorporating option /X provides a control for external coin sorting flaps. The control signals of the microprocessor are transmitted via 3 additional output lines.
wh Münzprüfer Dietmar Trenner GmbH, Germany Technical Manual EMP 8x0.00/04/13 v5 coin exits the coin selector. The coin selector will not accept any additional coins during this hold time unless they are of the same type as those then being sorted. Optionally, the hold time can be shortened by programming at the factory. The hold time will be cancelled by briefly activating the general blocking line.
Technical Manual EMP 8x0.00/04/13 v5 2.10 2.10.1 wh Münzprüfer Dietmar Trenner GmbH, Germany Safety Features Coin on a String (Strimming) The EMP 800 v5 is equipped with multiple safety functions to prevent almost every coin-on-a-string manipulation. As an additional security the coin selector can signal attempts of manipulation to the machine controller. It is also possible to block coin acceptance for a programmed time in order to make further attempts of manipulation more difficult.
wh Münzprüfer Dietmar Trenner GmbH, Germany Technical Manual EMP 8x0.00/04/13 v5 If a coin is still identified in the light barrier after 200 ms have passed, the message will be repeated. During this time, coin acceptance is blocked. 2.10.3 Additional External Strimming Detection (Option /Z) For certain applications an additional strimming detector to avoid manipulation is recommended, especially when working with an escrow.
Technical Manual EMP 8x0.00/04/13 v5 2.11 2.11.1 wh Münzprüfer Dietmar Trenner GmbH, Germany Further Options Power Supply Connections Reversed (Option /A) The polarity of the power supply inputs are reversed with this option, i.e. pin 1 of the EMP connector is UB (instead of GND) and pin 2 is GND (instead of UB). As there is no output channel being used for the reject signal, 7 output channels are now available. This version is especially designed for gaming machines on the Spanish market. 2.11.
wh Münzprüfer Dietmar Trenner GmbH, Germany 3.2 Technical Manual EMP 8x0.00/04/13 v5 SCI Interface The EMP 800 v5 communicates through a serial interface with the following specifications: data format: 9600 Baud, 1 start bit, 1 stop bit, no parity, 8 data bits, separate send and receive lines. high level low level + 5V 0V logical 0 logical 1 The SCI interface of the coin selector can be programmed to operate in one of two modes: 1.
Technical Manual EMP 8x0.00/04/13 v5 wh Münzprüfer Dietmar Trenner GmbH, Germany Value of the data bytes (X: value between 0 and 9) Ascending Value FXh EXh DXh CXh MSD (Most Significant Digit) LSD (Least Significant Digit) The EMP 800 v5 is always a master device when it is in SCI Mode. The SCI interface transfers 5 bytes with a refresh frequency of 5 Hz or after each result. Definition of the 5th byte: Meaning value of the 5th byte (HEX) 70H ... 7FH 80H ...
wh Münzprüfer Dietmar Trenner GmbH, Germany Technical Manual EMP 8x0.00/04/13 v5 Example: transferred data, binary programmed value of the accepted coin data, hexadecimal Chan. 1 20.00 1100 000 1101 0000 1110 0000 1111 0010 1000 0001 C0 D0 E0 F2 80 Chan 2 05.00 1100 0000 1101 0000 1110 0101 1111 0000 1000 0010 C0 D0 E5 F0 81 Chan 3 00.50 1100 0000 1101 0101 1110 0000 1111 0000 1000 0011 C0 D5 E0 F0 82 Chan 4 00.25 1100 0101 1101 0010 1110 0000 1111 0000 1000 0100 C5 D2 E0 F0 83 Chan 17 00.
Technical Manual EMP 8x0.00/04/13 v5 3.3 wh Münzprüfer Dietmar Trenner GmbH, Germany Multi Drop Bus (MDB) The coin selector can be set up to communicate with the machine controller using the MDB protocol. wheasy 3 can be used to program this setting. Select “Settings”, then “Operating Mode“. Choose MDB. Also be sure that the “Multi Drop Bus” check box is checked under “Configuration,” “B-Values” and then select the “Mode” tab. ! 3.3.
wh Münzprüfer Dietmar Trenner GmbH, Germany 3.3.3 Technical Manual EMP 8x0.00/04/13 v5 Basic Commands Command RESET Code 78h Data - The acceptance of coins is blocked. The response to the next poll is 07h (Reset).
Technical Manual EMP 8x0.00/04/13 v5 wh Münzprüfer Dietmar Trenner GmbH, Germany 1) If “Report 32 channel” has been activated (“Configuration”, “B-values” and “Receipt” tab) the channels 1 to 16 are reported with 80h to 8Fh and channels 17 to 32 are reported with 70h to 7Fh. This is a special wh Münzprüfer function, as the MDB specifications only define for a maximum of 16 coin channels.
wh Münzprüfer Dietmar Trenner GmbH, Germany Command Channel assignment Y1 Y2 – Y9 Y2 Y3 ! Technical Manual EMP 8x0.00/04/13 v5 Code 7Eh Data to the Coin Selector 9 Bytes Y1 to Y9 Number of the main coin box Assignment of the channel/shaft, one nibble each Channel 1/2 2/3 The given default coin sorting sequence is reverted to after a reset.
Technical Manual EMP 8x0.00/04/13 v5 wh Münzprüfer Dietmar Trenner GmbH, Germany the power on Reset, because this information must be transferred first after the poll command. There may not be enough time to do this if the coin selector has to be instantly ready to accept coins. A coin type command, which is sent from the machine controller to the coin selector is stored in the EEPROM in this mode and therefore still valid after a power on reset until the next coin type command is received. 3.3.4.
wh Münzprüfer Dietmar Trenner GmbH, Germany 3.4 Technical Manual EMP 8x0.00/04/13 v5 cctalk interface A 4-pin JST connector B 4B-XH-A is used for the cctalk interface PIN Nr. 1 2 3 4 Connection UB (10 ... 16 Vdc) Not used GND Data Line (Bi-directional) Coin selector selectors to be used with cctalk interface have to be set to MDB. The coin selectors recognises automatically the active protocol of the connected controller. 3.4.1 Command overview Header Function EMP8x0.
Technical Manual EMP 8x0.
wh Münzprüfer Dietmar Trenner GmbH, Germany 3.4.2 Technical Manual EMP 8x0.00/04/13 v5 193 Request fraud counter [000] [000] [000], not supported 192 Request build code Provides 16 ASCII codes technical specification 185 Modify coin id Actually not supported, changes are only possible using wheasy 3 from version 3.
Technical Manual EMP 8x0.00/04/13 v5 3.4.3 wh Münzprüfer Dietmar Trenner GmbH, Germany $9E General blocking 2 Coin blocked $9F EMP busy 13 Not ready cctalk adjustments using wheasy 3 Using wheasy 3 all cctalk settings can be carried out under “configuration” – “cctalk”. Figure 13 shows the window with the cctalk adjustments. Coin ID according to cctalk specifications as well as initial address of coin selector can be set here.
wh Münzprüfer Dietmar Trenner GmbH, Germany Figure 14 Technical Manual EMP 8x0.00/04/13 v5 Example of an EMP 800 v5 Label At the top is printed the exact type of coin selector. In this example: EMP 800.00 v5 At the end of the same line you find the installed options. In this example: /X Control for external sorting flaps On the left, besides the barcode (turned 90°) is the serial number and the week and year of manufacture. The same information is contained in the bar code.
Technical Manual EMP 8x0.00/04/13 v5 wh Münzprüfer Dietmar Trenner GmbH, Germany The output line is specified directly for the EMP 8x0.00 v5, which is a number between 1 and 6. The output line combination is given in the hexadecimal equivalent for binary code in the EMP 8xx.04 v5. 5 Maintenance The EMP 800 v5 is an extraordinarily robust coin selector and operates relatively maintenance free.
wh Münzprüfer Dietmar Trenner GmbH, Germany 6 Technical Manual EMP 8x0.00/04/13 v5 Connecting Diagrams Figure 15 Connecting diagram EMP 8x0.00 v5 Figure 16 Connecting diagram EMP 8x0.04 v5 EMP8x0.00/04/13 v5 Version 1.
Technical Manual EMP 8x0.00/04/13 v5 7 wh Münzprüfer Dietmar Trenner GmbH, Germany EG Conformation Declaration Product name: EMP 8x0.00 v5, EMP 8x0.04 v5 and EMP 8x0.