Install the appliance in a safe and suitable place that meets installation requirements.
Keep the minimum distance from other appliances and units.
Before mounting the appliance, check if the oven door opens without restraint.
The appliance is equipped with an electric cooling system. It must be operated with the
electric power supply.
The built-in unit must meet the stability requirements of DIN 68930.
Cabinet minimum height (Cabinet under the work‐
top minimum height)
578 (600) mm
Cabinet width 560 mm
Cabinet depth 550 (550) mm
Height of the front of the appliance 594 mm
Height of the back of the appliance 576 mm
Width of the front of the appliance 595 mm
Width of the back of the appliance 559 mm
Depth of the appliance 567 mm
Built in depth of the appliance 546 mm
Depth with open door 1027 mm
Ventilation opening minimum size. Opening placed
on the bottom rear side
560 x 20 mm
Mains supply cable length. Cable is placed in the
right corner of the back side
1500 mm
Mounting screws 4 x 25 mm
2.2 Electrical connection
WARNING!
Risk of fire and electric shock.
All electrical connections should be made by a qualified electrician.
The appliance must be earthed.
Make sure that the parameters on the rating plate are compatible with the electrical ratings
of the mains power supply.
Always use a correctly installed shockproof socket.
Do not use multi-plug adapters and extension cables.
47/208