11.2 Electrical installation
WARNING!
Only a qualified person must do
the electrical installation.
The manufacturer is not responsi-
ble if you do not follow the safety
precautions from the chapter
"Safety Information".
This appliance is only supplied with a
main cable.
11.3 Cable
Cable types applicable for installation or
replacement: H07 RN-F, H05 RN-F, H05
RRF, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.
For the section of the cable refer to the
total power (on the rating plate) and to the
table:
Total power
Section of the ca-
ble
maximum 1380
W
3 x 0.75 mm²
maximum 2300
W
3 x 1 mm²
maximum 3680
W
3 x 1.5 mm²
The earth cord (green / yellow cable) must
be 2 cm longer than phase and neutral
cables (blue and brown cables).