User manual

12. INSTALLATION
WARNING!
Refer to Safety chapters.
12.1 Gas connection
WARNING!
Before the gas connection,
disconnect the mains plug
from the mains socket or
deactivate the fuse in the
fuse box. Close the primary
valve of the gas supply.
The gas supply ramp is on the rear side
of the appliance.
WARNING!
Do not use rubber flexible
pipes!
Do not fully put the oven into the built-in
cabinet (approximately 30 cm).
Connection with a flexible metallic
pipe or a rigid metallic pipe:
A B C
A. Gas supply ramp, end of shaft with
ramp
B. Washer
C. Elbow
Put the supplied gasket between the pipe
and the gas supply ramp. Turn the pipe
to the 1/2" gas supply ramp.
1. Use a 22 mm spanner to tighten the
nuts. Keep the gas supply ramp in
the correct position. Do not apply
force to the gas supply circuit.
WARNING!
Do not use a flame to
check for leaks!
2. Fully move the oven into the built-in
cabinet.
WARNING!
Do not squeeze the gas
supply ramp and the
pipe when you move the
oven into the built-in
cabinet.
3. Seal the connection correctly. Use a
leak detection to control it.
WARNING!
Only for Russia: this
appliance operates with the
natural gas G20 20 mbar.
Before the gas connection, it
is important to adjust the
setting to the correct type of
gas (G20 13 mbar). Refer to
the instructions in
"Adjustment to different
types of gas".
12.2 Adjustment to different
types of gas
Let only an authorized
person do the adjustment to
different types of gas.
If the appliance is set for
natural gas you can change
it to liquid gas, with the
correct injectors.
The gas rate is adjusted to
suit.
WARNING!
Before you replace the
injectors, make sure that the
gas knobs are in the Off
position. Disconnect the
appliance from the electrical
supply. Let the appliance
cool down. There is a risk of
injury.
12.3 Oven injector replacement
1. Remove the bottom plate of the oven
cavity (A) to get access to the oven
burner (B).
ENGLISH 19