User manual

6 installation warnings/installation instructions electrolux integrated barbecue
warning
• Thisapplianceshallonlybeusedinanaboveground,
open air situation with natural ventilation without
stagnant areas, where gas leakage and product of
combustion are rapidly dispersed by wind or natural
convection. This barbecue has been designed for
outdoor use only. Refer to diagrams below.
• Neverinstallthisbarbecueinsideanybuilding,garage,
shed or breezeway or inside a boat, caravan or
recreational vehicle. This is to prevent the possibility of
fire or carbon monoxide poisoning or asphyxiation.
• Anyenclosureinwhichthisapplianceisinstalledshall
comply with one of the following:
An enclosure with walls on all sides, but at least
one permanent opening at the ground level and no
overhead covering.
Within a partial enclosure that includes an overhead
cover and no more than 2 walls.
Within a partial enclosure that includes an overhead
cover and more than 2 walls, the following shall apply:
at least 25% of the total wall area is completely
open and at least 30% of the remaining wall area
is open and unrestricted
• Inthecaseofbalconies,atleast20%ofthetotalof
the side, back and front wall areas shall be and remain
open and unrestricted.
Outdoor area example 1
Outdoor area example 2
Outdoor area example 3
Outdoor area example 4
Outdoor area example 5
Installation warnings
Choosing a location
• Thisappliancemustnotbeinstalledonanycombustible
material. A minimum clearance from any combustible
materials is 450mm (18”).
• Theverticalclearanceabovethecookingsurfacetoany
combustible materials must be at least 600mm.
• Thisappliancemustbeinstalledaccordancewith
Australian Standards AS 4557 and AS 5601 and in
accordance with local authority.
• WhenusingLPGinanenclosureventilationmustbe
provided. Gas is highly explosive and can cause serious
injury and damage to property if allowed to accumulate
and then be ignited.
• Thisbarbecueisintendedtobebuiltintoabenchtop
with a minimum depth of 600 mm.
• Avoidwindypositionsasthiswillaffectcooking
performance and burner efficiency. If this situation
cannot be avoided some shielding may be necessary.
The mounting enclosure
• Thebarbecuerequiresanon-combustiblebarrierunder
the barbecue to prevent excessive temperatures being
accessed. The barrier panel is to be placed 30mm
under the base of unit. There are spacers added to
bottom of unit to prevent barrier panel being too close
to barbecue base. Refer to diagram on next page.
• Themountingenclosuremustbeconstructedfrom
non-combustible materials. Suitable materials for
construction include masonry, granite, marble,
Hardiplank
®
, Villaboard
®
over a metal frame or tiles.
• Thisappliancerequiresventinginthefrontwallofthe
enclosure. See diagram below for details.
• Thisappliancecanbemountedeitherinanislandtype
bench or a bench with a splashback. Please read the
specific requirements for each mounting situation.
Island style installation
• Ifthisapplianceisinstalledinanislandmount,itcanbe
centrally positioned. Special attention should be given
to the overall size of the island top to consider the hood
open and the overhang. Please see below.
• Thecut-outsizerequiredis1025mmx502mm(see
diagram).
warning
• Thisappliancerequiresventing.Anopenareaas
indicated below must be allowed for. A suitable grille can
be fitted if desired. This vent area is to allow air into the
enclosure for the correct combustion of gases and for
the correct exhausting of the products of combustion. In
the case of LPG the gas is heavier than air, this vent in
the situation where there may be a leak allows the gas to
escape from the enclosure. This vent must be
700mm x 25mm minimum and positioned centrally
135mm below the mounting surface. (see diagram).
Installing in a bench with a splashback
• Thesplashbackmustbemadefromanon-combustible
material.
• Inthecaseofmountingthisapplianceagainstawall
or fence it is imperative that care be taken to ensure
the isolation of combustible materials. All combustible
materials must be kept 450mm away from the
barbecue.
Installation instructions
both ends
open
open side at
least 25% of
total wall area
30% or more
in total of the
remaining wall
area is open and
unrestricted
open side at
least 25% of
total wall area
30% or more
in total of the
remaining wall
area is open and
unrestricted