User manual

Long periods of non-operation
Do these steps when you do not use the
appliance for a long period:
1. Disconnect the mains plug from the
mains socket.
2. Close the water tap.
3. Keep the door open to prevent unpleas-
ant smells.
4. Keep the inner side of the appliance
clean.
Frost precautions
Caution! Do not install the appliance
where the temperature is below 0 °C.
The manufacturer is not responsible for
damage because of frost.
If not possible, empty the appliance and
close the door. Disconnect the water inlet
hose and remove water from the water inlet
hose.
Moving the machine
Do these steps to move the appliance:
1. Disconnect the mains plug from the
mains socket.
2. Close the water tap.
3. Remove the appliance and the hoses.
4. Do not tilt the appliance during trans-
port.
WHAT TO DO IF…
The appliance does not start or stops dur-
ing operation.
If there is a fault, first try to find a solution to
the problem yourself. Refer to following
charts. If you cannot find a solution to the
problem yourself, contact your dealer or the
Customer Care Centre.
Warning! Switch the appliance off
before you do the suggested corrective
actions.
Fault code and malfunction Possible cause and solution
The running program light contin-
ues to flash
The Ready indicator light flashes
once
The appliance does not fill with wa-
ter
The water tap is blocked or restricted with limescale.
Clean the water tap.
The water tap is closed.
Open the water tap.
The filter in the water inlet hose is blocked.
Clean the filter.
The installation of the water inlet hose is not correct. The
hose can be kinked or squashed.
Make sure that the installation is correct.
The running program light contin-
ues to flash
The Ready indicator light flashes
twice
The appliance does not drain
There is a blockage in the sink spigot.
Clean the sink spigot.
The installation of the water drain hose is not correct. The
hose can be kinked or squashed.
Make sure that the installation is correct.
The running program light contin-
ues to flash.
The Ready indicator light flashes
three times.
The anti-flood device operates
Close the water tap and contact your Customer Care Cen-
tre.
The program does not start The appliance door is not closed.
Close the door.
Mains plug is not connected.
Plug-in appliance to the mains.
The fuse has blown out in the household fuse box.
Replace the fuse.
Delay start is set.
Cancel the delay start to start the program immediately.
16 electrolux