Installation

15 ENGLISH
Fig.3.4.4-3
Do not place drain piping as indicated
below:
Fig.3.4.4-4
3.5 Electrical Installation
3.5.1 Safety Precautions
Electrical safety rules before starting the
installation:
1. A dedicated power supply circuit and
breaker should be provided for the
products which are not supplied with
a service cord and plug in accordance
with local electrical safety regulations.
2. The circuit breaker must have the
functions of magnetic tripping and heat
tripping to prevent short circuit and
overload.
3. The appliance shall be installed in
accordance with national wiring
regulations.
4. A circuit breaker with proper capacity
must be installed.
5. In case of problems in power supply,
the air conditioner must not be installed
before the customer xes the problem.
6. Be sure the power supply matches the
air conditioner.
7. Ensure the live wire, neutral wire and
earth wire in the power socket are
properly connected.
8. Inadequate or incorrect electrical
connections may cause electric
shock, re or some electrical parts to
malfunction.
9. Before performing any electrical work,
turn off the main power to the system.
NOTE:
Refer to Appendix(2) for correlative
specs about the Electrical Installation.
Earthing Requirements
1. The unit must be reliably earthed and
connected to the special earth device
by the qualied electrician.
2. The yellow-green wire in air conditioner
is the earthing wire which can not be
used for other purposes. Improper
earthing may cause electric shock.
3. The earth resistance should accord to
the national wiring regulation.
4. The user’s power must have reliable
earthing terminal. Do not connect the
earthing wire with the following:
Water pipe
Gas pipe
Contamination pipe
3.5.2 Installation of Indoor
Electric Wires
1. Open the front panel and remove the
wiring cover.
Fig.3.5.2-1
Downward
slope
Do not rise
Water leakage Water leakage
Water leakage
Accumulated
drain water
Tip of drain
hose dipped
in water
Space less
than 50mm
Air
Ditch
Wiring cover