Installation

7 ENGLISH
2.4 Installation site
Do not install the unit in areas with:
strong heat sources;
vapours or ammable gases;
contamination with oil particles;
high frequency electromagnetic
equipment (e.g. welding equipment
or medical devices);
high salinity (e.g. close to coastal
areas);
sulphuric gas (e.g hot water springs);
poor air quality.
Indoor unit
Maintain the minimum installation
distances specied in this document.
Do not block the air inlet or the air
outlet.
Do not use the unit in places with
extremely high humidity.
Install the indoor unit out of reach of
children.
The wall must be strong enough to
support the weight and vibration of the
unit.
Install the indoor unit at least 230 cm
above the oor surface.
Leave sufcient space for cleaning and
maintenance.
The air lter should remain accessible.
Leave at least 1 m distance between
the unit and other electrical appliances.
Install the indoor unit in a place where
the condensate water can be easily
drained.
Install at a location protected from
direct sunlight.
Outdoor unit
Maintain the minimum installation
distances specied in this document.
Do not block the air inlet or the air
outlet.
Install the outdoor unit out of reach of
children.
Install the outdoor unit where there is
sufcient ventilation.
Install the outdoor unit where produced
noise and airow will not disturb
neighbors or animals.
Install the outdoor unit in a dry place.
Install the outdoor unit in a place not
exposed to direct sunlight or strong
wind.
Install the outdoor unit in a place can
support the weight and vibration of the
unit.
Leave sufcient space for cleaning and
maintenance.
Safety precautions for electrical appliances
Use a dedicated mains circuit.
The unit must be properly grounded.
Install a Residual-current device (RCD)
to protect against personal injury in
case of leakage currents.
The installation must comply with local
electrical safety regulations and with
other relevant local regulations.
The unit must be installed in
accordance with national wiring
regulations.
Do not subject the mains cable to force.
The distance between the unit and heat
sources is at least 1.5 m.
NOTE
Make sure that the live wire, the neutral
wire and the ground wire in the mains
socket are properly connected.
Inadequate or incorrect electrical
connections can cause electric shock
or re.