GEFRIERSCHRANK - CONGELATEUR - CONGELATORE - FREEZER GEBRAUCHSANLEITUNG - MODE D`EMPLOI LIBRETTO D’ISTRUZIONI - INSTRUCTION BOOK EUF 1056 DE FR IT GB 200380406 SV/E/13. (06.
GB Before installing and using the appliance read this user's instruction book carefully. It contains safety precautions, hints, information and ideas. If the refrigerator is used in compliance with the instructions written, it will operate properly and provide you with greatest satisfaction. The symbols below help you to find things more easily: Safety precautions Warnings and information at this symbol serve safety for you and your appliance.
GB Cont ents Important safety information ...................................................................................................................40 General safety precautions ......................................................................................................................40 Precautions for child safety ......................................................................................................................40 Safety precautions for installation .................
GB Im por t ant saf et y inf ormation General safety precautions Keep these instructions and they should remain at the appliance when moving away or changing owner. This appliance is designed for storing and freezing food, domestic use according to these instructions only. Specialised companies that are qualified to do so by the manufacturer must carry out service and repairs including repairing and changing the power cord. Accessory parts supplied by them should be used only for repairing.
GB Ins tr uctions f or the User General information The official designation of the appliance is home freezer. According to this the appliance is suitable for storing frozen and deep-frozen food, freezing products in quantity given in the user's instructions at home and making ice. The appliance can meet the requirements of standards between different temperature limits according to the climate class. The letter symbol for climate class can be found on the data plate.
GB Ins tr uctions f or the Ins t aller Technical data Model Gross capacity (l) Net capacity (l) Width (mm) Height (mm) Depth (mm) Energy consumption (kWh/day) (kWh/year) Energy class, according to EU Standards Freezing capacity (kg/24h) Rising time (h) Rated current (A) Weight (kg) EUF 1056 100 80 595 850 635 0,575 210 A 9 13 0,5 40 Transportation, unpacking It is recommended to deliver the appliance in original packaging, in vertical position considering the protective warning on packaging.
GB Placement The ambient temperature has an effect on the energy consumption and proper operation of the appliance. When placing, take into consideration that it is practical to operate the appliance between ambient temperature limits according to the climate class that is given in the chart below and can be found in the data label. Class of climate Ambient temperature SN +10 ... +32 °C N +16 ... +32 °C ST +18 ...
GB Switch and indicators A) On/off indicator green B) Thermostat and on/off switch C) Quick freeze indicator yellow D) Acoustic signal stop and quick freeze switch E) Alarm indicator red Operation and use Installation Insert the plug into the socket. In order to switch on the product, turn the thermostat (B) to a temperature lower than << -16°C >>. The green, yellow and red indicators will light up. The lighting up of the on/off indicator (A) means that the product is switched on.
GB lighting until the internal temperature has reached a level required for the safe conservation of frozen food. Temperature problem: Under normal operating conditions, the internal temperature of the freezer will ensure the long-term conservation of the stored food. When such temperature rises above a certain level (-12°C), it will trigger an acoustic and light alarm. The light alarm is a continuous red light (E), while the acoustic alarm is an intermittent sound.
GB The appliance and environment This appliance does not contain gasses which could damage the ozone layer, in either its refrigerant circuit or insulation materials. The appliance shall not be discarded together with the urban refuse and rubbish. Avoid damaging the cooling unit, especially at the rear near the heat exchanger. Information on your local disposal sites may be obtained from your municipal authorities. The materials used on this appliance marked with the sympol are recyclable.
GB Trouble shooting During operation of the appliance some smaller but annoying trouble can often occur, which does not require calling a technician out. In the following chart information is given about them to avoid unnecessary charges on service. We draw your attention that operation of appliance goes with certain sounds (compressor- and circulating sound). This is not trouble, but means normal operation.
GB Change of door opening direction Should the setting-up place or handling demand it, door-opening direction can be refitted from right-handed to left-handed. Following operations are to be done on the basis of figures and explanations: Break the circuit of the appliance. Tilt back the appliance carefully so that the compressor can not touch the floor. It is recommended to ask another person for help, who can keep the appliance at this position safely.
GB S t or age time char t Storage time of deep-frozen and frozen products Foods -18°C Vegetables: green beans, green peas, mixed vegetables, marrow, corn, etc. Ready-cooked foods: vegetable dish, trimmings, with meat, etc. Ready-cooked foods: sirloin steaks, stew from knuckle of ham, meat from pig pudding, etc. Foods from potatoes, pasta: mashed potato, gnocchi, dumpling, pasta filled with jam, chips Soups: meat-broth, soup from green beans, soup from green peas, etc.
50 SV/E/13. (06.
51
Dipl. Ing. Ing. dipl. Unsere Kundendienst-Telefonnummer: Le numéro de téléphone de notre service après-vente: Il nostro numero di telefono del servizio clientela: Our customer service telephone number: 0848 559 111 oder unter ou sur Internet oppure su Internet or in the internet Dipl. Ing. FUST AG Riedmoosstrasse 3172 Niederwangen-Bern Tel. (031) 980 11 11 Dipl. Ing. FUST AG An der Rheinstrasse 4414 Füllinsdorf Tel. (061) 906 95 00 Dipl. Ing. FUST AG Dipl. Ing. FUST AG Mythen-Center 6430 Schwyz Tel.