17. Appendices
0199 2
17
- CP.15 allows to select the parameters CP.16 to CP.24 in the various sets (control terminal
diconnected).
0 : Selection of the set 0 for programming (diconnected terminal).
16 : Selection of the set 1 for programming (diconnected terminal).
32 : Selection of the set 2 for programming (diconnected terminal).
48 : Selection of the set 3 for programming (diconnected terminal).
64 : Selection of the set 4 for programming (diconnected terminal).
80 : Selection of the set 5 for programming (diconnected terminal).
96 : Selection of the set 6 for programming (diconnected terminal).
112 : Selection of the set 7 for programming (diconnected terminal).
Nota : reset CP.15 to 0 after CP.16 to CP.24 parameters programming, it's imperative to
make this value at CP.15, for correct working of the machine.
- CP.16 to CP.24 are parameters for read and write allowing variator setting.
Parameters writing may be forbidden by the code no. 100 in the parameter CP.00.