9. Installation
0102 26
9
Compressed air connection
The customer should arrange the installation
of filter/lubricator device, as well as a pres-
sure regulator (manometer) on the ma-
chine's compressed air supply.
The manual stopping valve lockable in
closed position (supplied) should be in-
stalled on the machine's compressed air
supply.
The supply pipe should accept a pressure of
at least 1 Mpa (10 bar) (145 psi).
Connection diameter : rapid action hose
coupling DN 6 (1.24") for hose Ø 6/8 mm.
Nota : to avoid too big head losses, the
compressed air supply pipe should be
bigger in diameter than the coupling
diameter (DN 8 for example) ; in this
case, put a 6/8-8/10 adapter.
Advised pressure : 550-700 kPa
(5.5-7 bar) (80-120 psi)
Minimum pressure: 550 kPa (5.5 bar) (80 psi)
Maximum pressure : 700 kPa (7 bar) (102 psi)
Consumption 50 l/h
D0690
1
4
7
2
5
8
3
6
9
0
Compressed
air