30" Electric & Induction Built-In Ranges
EW30ES80R & EW30IS80R
Overall
depth
including
oven door
in 90° open
position –
47
9
/16"
28
5
/16"
Side
27
1
/2"
25
3
/4"
Front
30"
31
1
/2"
35
3
/4"
Adjustable
to
36
5
/8"
13
/16"
35
7
/8"
min.
36
5
/8"
max.
Front Face of Cabinet
22
7
/8"
min.
23
1
/4"
max.
1
1
/8"
21
3
/4"
min.
22
1
/8"
max.
**
Countertop
13"
max.
30"
min.
18"
min.
24"
min.
1
/2"
min.
WALL
Hatched area
should be flat
and leveled
1
1
/2"
max.
Shave raised
edge to clear
space for
31
1
/2" wide
cooktop rim
30
±
1
/16"
*
21
3
/4"
min.
22
1
/8"
max.
**
1
/2"
min.
Locate grounded junction box
or wall outlet 8"
-
17" from right
cabinet and 2"- 4" from floor
Locate cabinet
doors 1" min.
from cutout
opening
3
/8"
min.
*Cabinet and countertop
cutout width should match
**24" with optional
backguard installed
Power
supply
location
(left
bottom
rear)
24" min. clearance
with protected cabinet bottom
30" min. for unprotected
Approx.
1
7
/8"
31
1
/2"
(critical)
30
±
1
/16"
*
INDUCTION BUILT-IN RANGE
EW30IS80RS
To reduce risk of fire when using overhead cabinetry, install range hood that
projects horizontally a recommended minimum of 5" beyond bottom of cabinets.
When installing range into existing cutout depth greater than 22-1/8",
optional 2" Rear Filler Kit available.
Countertop Preparation
For detailed preparation instructions, refer to installation guide on the web.
Flat square-finish (flat) countertop requires no preparation since rangetop
flange lays directly on countertop edge.
Formed front-edged countertops require front molded edge to be shaved
flat 3/4" from each front corner of opening.
Tile countertops may need cut back 3/4" from each front corner of opening
and / or rounded edge flattened.
For existing cutout width greater than 30-1/16" reduce the 3/4" overlap
dimension or for cutout width of 29", replace actual side trim panels with
smaller side trim panels, available with optional Side Trim Kit (refer to
detailed kit installation instructions).
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
2" Rear Filler Kit: Black – (PN # 903113-9010).
Side Panel Kit: Black – (PN # A01529901).
30" Induction Built-In Range Specifications
Product Weight – 250 Lbs.
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz,
fused on both sides of line with ground. (If local code permits, range may
be connected by hard-wiring or by means of power supply cord kit.)
Connected Load (kW Rating) @ 240 / 208 Volts = 16.0 / 12.0 kW
Amps @ 240 / 208 Volts = 66.7 / 57.7 Amps
Recommended Circuit Breaker – 40 Amps
Always consult local and national electric codes.
Make sure wall coverings around range can withstand heat generated by range.
Linoleum or any other synthetic floor covering located beneath range, must
be capable of withstanding minimum heat of 90° F above room temperature
without shrinking, warping or discoloring. Insulating pad or 1/4"-thick
plywood required between range and a carpeted floor.
Countertop MUST be level in all directions and adjustable range height at
least 1/16" greater than tallest cabinet height, to ensure metal rangetop
flange will fit properly on countertop edge.
When installing optional Backguard Kit, cutout depth of 21-3/4" minimum /
22-1/8" maximum needs increased to 24".
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets installed
to either side of appliance must be no less than maximum width of appliance.
Allow 24" minimum clearance between rangetop and bottom of cabinet
when bottom of wood or metal cabinet is protected by not less than 1/4"
flame-retardant millboard covered with not less than No. 28 MSG sheet
steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper. Allow 30"
minimum clearance when cabinet is unprotected.