36" GAS RANGE INSTALLATION INSTRUCTIONS
5
Connect Fuel Supply
5.1
Fuel Supply Connection
This appliance must be installed,
grounded, and serviced by a qualied installer or service
technician.
Do not make connections too tight. The
regulator is die cast. Overtightening may crack the
regulator resulting in a gas leak and possible re or
explosion.
This appliance includes a regulator. The gas supply line
requires the following parts which are not supplied with
the appliance:
Manual shutoff valve
1/2" nipples (2)
1/2" are union adapter (2)
Flexible connector
The gas supply line to the shutoff valve should be
1/2"(1.27 cm) or 3/4"(1.9 cm) solid pipe.
Install the gas supply pipe to the pressure regulator in
the order shown in Figure 11. All connections should be
tightened with a wrench.
When using exible gas conduit on the range, allow
sufcient slack to pull the range outside the cutout for
cleaning or servicing.
Use pipe-joint compound made for use with Natural and
LP/Propane gas to seal all gas connections. If exible
connectors are used, be certain connectors are not
kinked.
Do not allow the exible conduit to get pinched between
the wall and the range.
Flare
Union
Flare
Union
GAS FLOW
Manual
Shutoff
Valve
Pressure
Regulator
On
Off
Flexible
Connector
Access
Cap
Nipple Nipple
Figure 11: Fuel supply connection ow
5.2
Check For Leaks
Do not use a ame to check for leaks from
gas connections. Checking for leaks with a ame may
result in a re or explosion.
After connecting the range to the gas supply, check the
system for leaks with a manometer. If a manometer is not
available, turn on the gas supply and use a liquid leak
detector (or soap and water) at all joints and connections
to check for leaks. Leaks will be indicated by bubbles
appearing at the connections or joints.
All openings in the wall or oor where the range is to be
installed must be sealed.
1. Tighten all connections if necessary to prevent gas
leakage in the cooktop or supply line.
2. Disconnect this range and its individual shutoff valve
from the gas supply piping system during any pressure
testing of the system at test pressures greater than
1/2 psig (3.5 kPa or 14"(35.56 cm) water column).
3. Isolate the range from the gas supply piping system by
closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig (3.5 kPa
or 14"(35.56 cm) water column).