Warning! Installation should
comply with local water authority
and building regulations’
requirements.
The appliance must be connected
to a cold water supply.
A minimum water pressure of 0.05
MPa (0.5 bar) is required for safe oper-
ation of the appliance.
If you cannot make the cold water con-
nection direct from the rising mains,
you may be able to operate the appli-
ance from your cold water storage sys-
tem.
There should be a minimum vertical
distance of 5.02 m (16.5 ft) between
the appliance’s inlet and the bottom of
the water storage tank.
WATER DRAINAGE
This appliance is designed to be perma-
nently plumbed into your home's drainage
system using one of the following methods.
1. Into a drainage standpipe
Firstly form a hook in the end of the drain
hose using the “U” piece” supplied.
“U” piece
supplied
Place the drain hose into your standpipe,
which should have an internal diameter of
approximately 38 mm thus ensuring there is
an air break between the drain hose and
standpipe.
38 mm (½”)
standpipe
diameter
30 cm (12”)
When discharging into a standpipe ensure
that the top of the standpipe is no more
than 90 cm (35.4'') and no less than 60 cm
(23.6'') above floor level.
electrolux 25