User Manual

15
Indoor Unit
pipe
Step 6: Piping Connection - Indoor Unit
B: Wrap the insulation material around the
connecting portion:
 Cover the indoor unit pipe and the connection
pipe with the heat insulation material. Bind
them together with vinyl tape so that there is
no gap.
A: Connecting the indoor unit tubing to the
connection piping:
 $OLJQWKHFHQWHUVRIWKHSLSHVDQGVXI¿FLHQWO\
WLJKWHQWKHÀDUHQXWZLWK\RXUKDQGV¿UVW
Cable ties
Pipings
Pipings
Flare nut
Flare nut
Indoor unit tubing
Torque
wrench
Indoor unit
tubing
6SDQQHU¿[HG
wrench
Torque
Spanner
Heat insulation
Insulation
material
Suction line
pipe
Liquid line
pipe
 7KHQWLJKWHQWKHÀDUHQXWZLWKVSDQQHUDQG
torque wrench by referring the following:
Connection pipe
Vinyl tape
(wide)
Wrap with vinyl tape
Vinyl tape
(narrow)
Pipe
Connection
cable
([FHVVLYHWRUTXHFDQEUHDNWKHQXWGHSHQGLQJ
on installation conditions.
 Ensure to Isolate separately the suction pipe
from the liquid pipe.
 Wrap the insulated pipes with vinyl tape in the
rear section for pipe housing. Fasten the power
cable to the pipes with vinyl tape.
 Wrap the piping, drain hose and power
cable tightly with vinyl tape so that they can
¿WLQWRWKHUHDUSLSLQJKRXVLQJVHFWLRQ
Outer diam.
(mm)
Torque
(N.m)
Additional
Torque (N.m)
Ɏ´ 15.7 (1.6kg.m) 19.6 (2.0kg.m)
Ɏ´ 29.4 (3.0kg.m) 34.3 (3.5kg.m)
Ɏ´ 49.0 (5.0kg.m) 53.9 (5.5kg.m)
Ɏ´ 73.6 (7.5kg.m) 78.6 (8.0kg.m)
caution