user manual Split Type Room Air Conditioner
Table of Contents Congratulations ....................................................................2 Safety Precautions ...............................................................3 Product´s Description ...........................................................5 Indoor Unit Display ...............................................................6 Remote Control.....................................................................6 Remote Control Description ............................................
Congratulations Congratulations and thank you for choosing Electrolux split-type air conditioner. We are sure you will find your new air conditioner a pleasure to use. Before you use the air conditioner, we recommend that you read through the entire user manual, which provides the description of the air conditioner and its functions.
Safety precautions Inside this manual you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the chart of troubleshooting tips on page 20-21. If you review the chart of troubleshooting tips first, you may not need to call for service.
Safety precautions caution Select the most appropriate temperature. It can save electricity. Do not keep windows and doors open for a long time during operation. It will result in insufficient performance. Do not block the air inlet or outlet. It will result in insufficient performance and cause malfunctions. Keep combustible materials away from the units at least 1m. It may cause fire. Do not step on the top of the outdoor unit or place heavy things on it. It may cause damage or injury.
Product Description Air inlet 2 Indoor Unit 1 13 3 4 5 Air Outlet 6 7 8 Outdoor Unit 9 12 11 Air inlet (rear) Fan Mode Light Turbo Healthy Temp Timer-On Timer-Off Swing Clock I feel Eco Air inlet (side) 10 Air Outlet 15 Front panel Remote control Digital display Remote control holder Healthy air filter (behind the dust filter) Refrigerant pipe (if applicable) Pre-dust filter Drain hose (if applicable) Horizontal air louvers Power cable (if applicable) Vertical air lou
Indoor Unit Display • If you keep the remote control in a position that hinders proper signal transmission, a time lag of up to 15 minutes may occur. Signal receiver I Feel indicator It lights when I Feel function is activated. Turbo indicator Illuminates during Turbo operation. Eco (Economy) indicator Illuminates when ECO function is in operation. Temperature indicator Displays the temperature settings when the air conditioner is in operation.
Remote Control Description Models with Cold-Plasma function Turbo Button Press this button in COOL or HEAT mode to put the fan into the high speed Turbo mode and the air conditoner will work at maximum power. Press again to cancel this function. Healthy Button Press this button to turn the Cold-Plasma function ON or OFF.
Remote Control Description Models without Cold-Plasma function Turbo Button Press this button in COOL or HEAT mode to put the fan into the high speed Turbo mode and the air conditoner will work at maximum power. Press again to cancel this function. X-Fan Button Press the X-Fan button to active the Self-Cleaning. After the unit is turned off the indoor fan will continue operation for 10 minutes to dry the indoor unit prevent from bacteria and mildew growing.
Remote Control Display Indicator Transmission Indicator: Displays when the remote control transmits signals to the indoor unit. Fan Speed Display Displays the selected fan speed in the following sequence: Turbo Display Displays when Turbo function is selected. “ ” (Low), “ Auto. I Feel Display Displays when I Feel function is activated. In Auto speed, only “ ” symbol displays. Eco Display Displays when Eco function is selected.
First Use 1 Ensure the unit is plugged in and power is available. 2 Be sure the batteries are inserted correctly in the remote control (the lights on the remote control will be on). 3 Set the time by Control buttons and confirm by pressing the Clock button. 4 Point the remote control to the indoor unit and press ON/OFF button to turn the unit on. The default operating mode is AUTO.
Start 1 ON/OFF Button Press this button to turn the air conditioner on. The temperature indicator on the indoor unit display lights on. 2 Mode Button Press to select DEHUMIDIFY. 2 Mode Button Press to select FAN. 3 Fan Button Press to select the desired fan speed at: Auto, Low, Medium and High. The default fan speed is Auto. 3 Control Buttons Set the desired temperature. Normally, set between 21ºC to 28ºC.
3 Control Buttons Set the desired temperature. Normally, set between 21ºC to 28ºC. 4 Fan Button Press to select the desired fan speed at: Auto, Low, Medium and High. The defaul fan speed is Auto. tips and information No fan speed indication disaplys on the remote control if Auto fan speed is selected. 3 Point the remote control to the indoor unit, confirm the set time by pressing the Timer-On button. symbol will stay on the remote control’s display.
1 Press the Timer-On button. 2 Set the desired time by pressing repeatedly or holding down the Control buttons until 18:00 shows in the display of the remote control. 3 Confirm the set time by pointing the remote control to the indoor unit and pressing again the Timer-On button. 4 Press the Timer-Off button. 3 Confirm the set time by pointing the remote control to the indoor unit and pressing again the Timer-On button.
Setting the Clock Economy (Eco) Operation Press Eco button in COOL or HEAT (if applicable) mode, the air conditioner will automatically increase (in COOL mode) or decrease (in HEAT mode) 1 C per hour over a 2 hour period. The set temperature will be steady for the next 5 hours then the unit will stop. This function permits more comfort and saves energy. This operation is recommended for bed time.
How to Use the Indoor Unit Additional Options 1 Smart Restart Function The air conditioner resumes automatically with the previous settings after a possible power failure. • When the louver moves to the desired direction, press the Swing button again and the louver will stay at where it is. • Press the Swing button again and the louver will start swing up and down automatically. 2 Removable Panel The front panel of indoor unit can be easily removed for cleaning and maintenance.
• Do not move the horizontal louver manually. Always use the Swing button. Moving the louver manually may cause malfunction during operation. If the louver malfunctions, stop the air conditioner and restart it. • Open angle of the horizontal louver should not be set too small, as cooling or heating performance may be impaired due to too restricted airflow area. • Do not operate the air conditioner with horizontal louver in closed position.
Cleaning and Maintenance Maintenance The following maintenance operations must be performed regularly.
Dust filter warning Do not touch or try to clean the cold plasma generator (if applicable). It may cause an electric shock. General maintenance Clean the Dust filter with a vacuum cleaner or water, then dry it up in cool place. If the air conditioner is not going to be used for a long period of time: • Operate in FAN only mode for 3~4 hours to allow the unit to completely dry out. Dust filter • Switch off the unit and pull out the power plug. Remove the batteries from the remote control.
• Defrosting Frost may form on the outdoor unit in heating operation when the outdoor temperature is low but humidity is high, resulting in low heating efficiency. environment that has a high relative humidity. • A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting. 4. Low noise of the air conditioner • You may hear a low hissing sound when the compressor is running or has just stop running.
Trouble Shooting The air conditioner is not user serviceable. Incorrect repair may cause electric shock or fire. Please contact an authorised service center for professional repair. warning If one of the following situations occur, immediately stop the air conditioner, disconnect the power, and contact the authorised service center. • If error code appear on the display window of indoor unit.
The following checks prior to contact may save you time and money. Malfunctions Cause Malfunctions The unit does not operate The unit does not operate if it is turned on immediately after it is turned off. This is to protect the unit. Please wait about 3 minutes. Water leakage of indoor unit • The humidity is high. • Condensing water overflows. • Drain hose is loose or obstructed. Odours are emitted • Some odours may be emmited from the indoor unit.
22