User manual

BURN-
ER
NORMAL
POWER
RE-
DUCED
POWER
Type of
gas
Pres-
sure
Injector di-
ameter
Usage
kW kW mbar mm g/h
3,00 0,72 Butane
G30
50 0,77 218,14
2,60 0,63 Propane
G31
50 0,77 185,68
Oven
2,70 0,90 Natural
gas G20
20 1,20 -
2,50 0,90 Butane
G30
50 0,63 181,78
2,15 0,78 Propane
G31
50 0,63 156,33
Grill
1,90 - Natural
gas G20
20 1,08 -
2,00 - Butane
G30
50 0,60 -
1,70 - Propane
G31
50 0,60 -
13.3 Gas Connection
Choose fixed connections or use a flexible
pipe in stainless steel in compliance with
the regulation in force. If you use flexible
metallic pipes, be careful they do not
come in touch with mobile parts or they
are not squeezed.
When you install and connect the
appliance, obey the directives:
SVGW- Gas principles G1: Gas
installation
EKAS- Form. 1942: Liquid gas
directive, Part 2
Cantonal instances regulations
(e.g. fire safety regulators)
13.4 Flexible nonmetal pipes
connection
If it is possible to easily control the con-
nection in its full area, you can use a flexi-
ble pipe. The flexible pipe must be tightly
attached by clamps.
Installation: use the pipe holder. Always
engage the gasket. Then continue with
the gas connection. The flexible pipe is
prepared for apply when:
it can not get hot more than room tem-
perature, higher than 30 °C;
it is no longer than 1500 mm;
it shows no throttles;
it is not subject to traction or torsion;
it does not get in touch with cutting
edges or corners;
it can be easily examined in order to
check its condition.
The control of preservation of the flexible
pipe consists in checking that:
it does not show cracks, cuts, marks of
burnings on the two ends and on its full
length;
the material is not hardened, but shows
its correct elasticity;
the fastening clamps are not rusted;
–expired term is not due.
If one or more defects are visible, do not
repair the pipe, but replace it.
When installation is complete,
make sure that the seal of each
pipe fitting is correct. Use a soapy
solution, not a flame!
The gas supply ramp is on the rear side of
the control panel.
ENGLISH 21