Service manual
10
Operation speeds:
Agitate Speed - RPM (Heavy Duty/Normal/Quick) 51 ± 4
Agitate Speed - RPM (Hand Wash) 35 ± 4
Spin speeds
Heavy Duty
Spin Speed R.P.M. (Low) 850 ±35
Spin Speed R.P.M. (Medium) 900 ± 39
Spin Speed R.P.M. (Max) 950 ± 39
Normal
Spin Speed R.P.M. (Low) 850 ±35
Spin Speed R.P.M. (Medium) 900 ± 39
Spin Speed R.P.M. (Max) 950 ± 39
Quick
Spin Speed R.P.M. (Low) 850 ± 35
Spin Speed R.P.M. (Medium) 900 ± 39
Spin Speed R.P.M. (Max) 900 ± 39
Delicates/Hand Wash
Spin Speed R.P.M. (Low) 450 ± 25
Spin Speed R.P.M. (Medium) 450 ± 25
Spin Speed R.P.M. (Max) 650 ± 30
Silk
Spin Speed R.P.M. (Low) 0 ± 0
Spin Speed R.P.M. (Medium) 0 ± 0
Spin Speed R.P.M. (Max) 0 ± 0
Drain/Spin
Spin Speed R.P.M. (Low) 850 ± 35
Spin Speed R.P.M. (Medium) 900 ± 39
Spin Speed R.P.M. (Max) 950 ± 39
Tub Pulley to Motor Pulley Ratio 16 TO 1
Tub Capacity 2.65 cu. ft.
Automatic Temperature Control Specifications
Regulated hot/coldsetings 149° ± 7° F
Regulated warm/warm and warm /cold settings 90° ± 7° F
Regulated cold/cold settings 70° ± 7° F
Neutral test point.
When measureing voltage between a point to neutral
insert one lead of the volt meter into the harness plug
with white wire that is connect to the line cord for the
neutral connection.