Service manual

40
that cavity to neutral allowing part of the incoming water
to enter the cavity.
When water is added to either the bleach or fabric softener
liquid, the mixture level rises between the two tubes above
the tube in the cavity and flows into the washer tub.
Since the end of the tube on the insert does not touch
the bottom of the cavity, a siphoning action is created.
When the solenoid activates and allows water into the
cavity, the added water creates an “overfill” condition and
starts the siphoning. The cavity then empty itself when
the water is turned off by the solenoid.
Auto Temp System
The auto temp system controls the minimum temperature
of the cold water setting (approximately 70° F.) and
maximum temperature of the warm and hot water setting
(approximately 90° F. and 150° F. ). Auto temp system
is made up of the control board and a positive thermal
sensor connected in the water hose between the water
valve and the dispenser.
Bleach and fabric softener dispensing are controlled by
the control board at specified times in the cycle by using
the electrical solenoids and redirecting some of the water
fill into their containers.
The bleach and the fabric softener cavities have tubes
molded into the bottom which allows the cavity to be
filled without being immediately dispensed into the
washer.
Bleach and fabric softener inserts fit into each respective
cavity and have a tube molded onto them. These tubes
are larger than the tubes in the cavity and are designed
to fit over the tubes, but not touch the bottom of the
cavity when the insert is installed. When the correct
time comes for the bleach or the fabric softener to enter
the tub the control board connects the solenoid behind
Cap
Water and Products
Cavity
Bypass
Water
Inlet
Tubes