Service manual

51
Bleach dispenser
does not operate.
Using the On line test
program activate the
bleach circuit. Measure
the voltage drop across the
bleach solenoid terminals.
120 VAC.
Defective
solenoid.
Defective
control.
0.
Bleach dispenser does not operate.
Note: Always check wiring
to the components.
Softener dispenser
does not operate.
Softener dispenser does not oper-
ate.
Note: Always check wiring
to the components.
Inspect the detergent
dispenser drawer. Is the
bleach cavity clean and the
cap in place.
Yes.
No.
Clean and
install the
cap.
Using the On line test
program activate the
softener circuit. Measure
the voltage drop across the
softener solenoid terminals.
120 VAC.
Defective
solenoid.
Defective
control .
0.
Inspect the detergent
dispenser drawer. Is the
bleach cavity clean and the
cap in place.
Yes.
No.
Clean and
install the
cap.
Note: The control board is the board in the console.
Note: The control board is the board in the console.