Service manual

56
Slow water fill.
Straighten hose and
turn the faucets
completely on.
Check the water hose for kinks and that
the faucets are turned completely on.
Hoses are kinked or
faucets not turned on
completely.
Note: Always check
wiring to the components.
Slow water fill.
Hoses are not
kinked and the
faucets are turned
on completely.
Disconnect the water hoses
at the faucets and check the
water pressure.
Water pressure is
below 10 psi.
Have homeowner
correct pressure
problem.
Disconnect the water hoses
at the washer, clean the valve
screens and check the hoses for any
restrictions.
Water pressure is
above 10 psi.
Defective control
board.
Unplug the wires from the sensor and
measure the resistance of the sensor.
Is the reading between 3,000 Ohms
and 163,000 Ohms.
Note: Always check
wiring to the components.
Warm water temperature above or cold water
temperature below specifiations.
Defective sensor.
Warm water temperature above or cold
water temperature below specification.
Display may show F 02.
Yes.
No.
Note: The control board is the board in the console.