3. Release the tab securing motor cover to pump and
slide the cover back and off.
4. Disconnect electrical harness plug from pump
motor.
5. Remove drain hose from drain and empty any
remaining water in hose. Use a large pot or pan.
6. Disconnect the hoses from the pump.
7. Remove two 5/16” hex head screws securing the
drain motor and pump assembly to cabinet base and
lift the assembly out.
Disassembling the drain pump:
1. Disconnect the washer from electrical supply.
2. Remove the drain pump from the washer.
3. The check valve is located in the output
connection of the pump. To remove the check
valve lift it off its tab.
4. To remove the rear pump housing, remove three
screws locking the housings together and pull the
housings apart. (Do not twist.)
To remove the air bell:
1. Disconnect washer from electrical supply.
2. Remove the front service panel.
3. Remove drain hose from drain and empty any
remaining water in hose. Use a large pot or pan.