Problem Possible cause Solution
The compressor operates
continually.
Temperature is set incor-
rectly.
Refer to "Operation".
Many food products were
put in at the same time.
Wait some hours and then
check the temperature again.
The room temperature is
too high.
Refer to climate class chart
on the rating plate.
Food products placed in
the appliance were too
warm.
Allow food products to cool
to room temperature before
storing.
The door is not closed
correctly.
Refer to "Closing the door".
The FastFreeze is switch-
ed on.
Refer to "FastFreeze ".
The water drainage plug
is not correctly positioned.
Position the water drainage
plug in the correct way.
Food products are not
wrapped properly.
Wrap the food products bet-
ter.
Temperature is set incor-
rectly.
Refer to "Operation" .
The compressor does not
start immediately after
pressing the FastFreeze, or
after changing the tempera-
ture.
This is normal, no error
has occurred.
The compressor starts after a
period of time.
Water flows inside the re-
frigerator.
The water outlet is clog-
ged.
Clean the water outlet.
Food products prevent
that water flows into the
water collector.
Make sure that food products
do not touch the rear plate.
Water flows on the floor. The melting water outlet is
not connected to the
evaporative tray above the
compressor.
Attach the melting water out-
let to the evaporative tray.
The temperature in the ap-
pliance is too low/too high.
The temperature regulator
is not set correctly.
Set a higher/lower tempera-
ture.
The door is not closed
correctly.
Refer to "Closing the door".
The food products' tem-
perature is too high.
Let the food products tem-
perature decrease to room
temperature before storage.