User manual

9.3 Other technical data
TOTAL POW‐
ER:
Gas original: G20 (2H) 20 mbar 10,6 kW
Gas replace‐
ment:
G30 (3+) 28-30 mbar 771 g/h
G31 (3+) 37 mbar 757 g/h
Electric supply: 220-240 V ~ 50-60 Hz
Appliance cate‐
gory:
II2H3+
Gas connec‐
tion:
G 1/2"
Appliance
class:
3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Rapid 2,95 0,75 119°
Semi-rapid 1,85 0,6 92
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Rapid 2,8 0,95 86 204 200
Semi-rapid 2,0 0,6 71 145 143
Auxiliary 1,0 0,33 50 73 71
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification KGS7524SX
Type of hob Built-in hob
Number of gas burners 5
ENGLISH 17