Finding Information Please read and save this guide Thank you for choosing Electrolyte, the new premium brand in home appliances. This Use & Care Guide is part of our commitment to customer satisfaction and product quality throughout the service life of your new appliance. We view your purchase as the beginning of a relationship. To ensure our ability to continue serving you, please use this page to record important product information.
Important Safety Instructions Important Safety Instructions Read all instructions before using this appliance. Save these instructions for future references Approved for residential appliances For residential use only Do not attempt to install or operate your appliance until you have read the safety precautions in this annual. Safety items throughout this manual are labeled with a WARNING or CAUTION based on the risk type.
Important safety Instructions READ AND SAVE THESE INSTRUCTIONS Important safety Instructions A CAUTION FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS, /N\ WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer, If you have questions, contact the manufacturer 8.
Important safety Instructions Electrical & Installation requirements READ AND SAVE THESE INSTRUCTIONS Electrical & Installation requirements Electrical requirements IMPORTANT Observe all governing codes and ordinances. It is the customer's responsibility: To contact a qualified electrical installer. To assure that the electrical installation is adequate and in conformance with National Electrical Code, EXPANSION 70 — latest edition”, or CSA Standards Canadian Electrical Code, Part 1 and 22.
List of Materials ese Ee Erse ws List of Materials Parts included in your hood Hood structure assembly with blower, transition. Lamps already installed. Grease fitter. Duct cover + Bottom. Top.
Installing the hood Installing the hood «For the most deficient air flow exhaust, use a straight run or as few elbows as possible. A CAUTION Vent unit to outside of building and recirculating. + On average 2 10 3 hours are necessary to complete installation (without considering cut to be done on wall and or on cabinet, installation of ducts , conduit and electrical connections to the mains}.
Installing the hood Examples of possible ducting Hashing and cap Pipe] Transition Vertical discharge Duct work installation guidelines For safety reasons, ducting should vert directly outdoors {not into an attic, underneath the house, into the garage or into any enclosed space). Keep duct runs as short and straight as possible. Duct fittings {elbows and transitions) reduce air flow efficiency. Back to back elbows and “S* turns give very poor delivery and are not recommended.
Mounting the duct cover bracket The duct bracket should be installed against the back wall and flush with the ceiling. This bracket will hold the telescopic duct cover in place at the top Secure the bracket to the wall: » Align the marked center line on the bracket with the center line on the wall. Mark 2 screw hole locations in the wall. Drill 5/16" pilot holes in the marked locations. Install wall fastener anchors. Drive wood screws, by hand, into the fastener to allow anchors to expand.
0 Installing the hood . . install supportable framing for hood support If drywall is present, mark the screw hole locations. Remove the template. Cut away enough drywall to expose 2 vertical studs at the holes location indicated by the template. Install two horizontal supports at least 4 X 27 between two wall studs at the bottom and upper mounting holes installation location. The horizontal support rust be flush with the room side of the studs.
. Mark “lower” wood screw holes locations in the wall using a pencil. Installing the hood Remove the hood. Drive “lower” wood screws, by hand. Remove S Crews. Mount the hood onto the “upper” screws. Drive and tighten the “upper” woad screws, by hand. Drive and tighten the “lower” wood screws, by hand.
sl Installing the hood Connecting the duct work s install duct work, making connections in the direction of airflow as illustrated. s Push duct over the exhaust outlet. * Wrap all duct joints and the flange connections with duct tape for an airtight seal. « Make the same connection in the wall or ceiling vent exit.
Making the electrical connections ON WARNING Electrical Shock Hazard Warning: Turn off at the service panel before wiring this unit, 120 Amp circuit required. ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH A WIRES, ONE OF WHICH YELLOWSTONE SERVES TO GROUND THE APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE MUST BE CONNECTED TO THE GROUNDING WIRE IN YOUR HOME ELECTRICAL SYSTEM, AND iT MUST UNDER NO CIRCUMSTANCES BE CUT OR REMOVED.
Control buttons 14 °° Mounting the duct cover + Secure the bottom of the duct with 2 assembly screws provided. + Position the duct cover over the mounted hood. « Slide the bottom of the duct onto the glass area. + Position the top of the duct over the duct mounting bracket. If a telescopic duct cover is used, grab the upper part of the telescopic duct cover, pull it and place it in the duct cover mounting bracket. « Secure the top of the duct with 2 assembly screws provided.
Features 19 Pes wN Blower and light controls Lamp housings Grease Filter Handle Grease Filter Canopy Duct cover + Top + Bottom Louver holes {User for Recirculating accessories}
Control buttons Control buttons This hood is equipped with an electronic motor and lamp control. The control is able to set 4 different fan speeds, tum ON/OFF light and has a timer function. In the following drawing are described the main key functions. 1 2 5 vod 6668 1. Light Button * Press lamp button to turn ON the light {Lamp state previously OFF), * Press lamp button to turn OFF the light (Lamp state previously ON}. 2.
Control buttons Special functions Special functions Clock programming The clock can be reprogrammed at any time except during an active timed function. * The clock can be displayed in a twelve hour format and valid clock times are from 1:00 to 12:59. * The clock can be reprogrammed pressing the “Timer” button for 5 seconds, and after, the clock can be adjusted with the and buttons. Colon ” will flash indicating clock programming mode.
1 2 Care and cleaning For Best results Continuous use of the fan system while cooking helps keep the kitchen comfortable and less humid. It also reduces cooking odors and soiling moisture that create a frequent need for cleaning. Turn the blower on before starting to cook. Use a rear burner when browning or pan frying meat, Open a window or inside door slightly.
Care and Cleaning Care and cleaning The deficiency of the range hood system depends on the cleanliness of the intake and filters. The frequency of cleaning depends on the amount and type of cooking. « Do not use the ventilating system without the filters in place or with grease-laden filters or surfaces. [A WARNING To avoid risk of fire and explosion do not use flammable liquids or solvents. Always unplug or disconnect the appliance from the power supply before servicing.
Clear and Cleaning Optional Charcoal Filters If the model is not vented to the outside, the alr will be recirculated through disposable charcoal filters that help remove smoke and odors. The charcoal filters cannot be cleaned. They must be replaced. The charcoal filters are clipped inside of each metal grease filter {mounting instructions included with charcoal fitters skiff. The charcoal filters should be replaced every 4-6 months (depending on hood usage).
Warranty Information Your appliance is covered by a one year limited warranty. For one year from your original date of purchase, Electrolyte will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed. used and maintained in accordance with the provided instructions. Exclusions This warranty does not cover the following: 1.