CARAVAN MANUAL RM 4400 RM 4401 Deutsch English Français Italiano Español Typ C40 / 110 821 2658-02 Seite page page pagina pagina 1 7 13 19 25 Svenska Dansk Norsk Nederlands Suomi Português sida side side pag. sivu cara 31 37 43 49 55 61 T.B.
OPERATING AND INSTALLATION INSTRUCTIONS FOR ELECTROLUX REFRIGERATORS INTRODUCTION CONTENTS We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it, but first a few well-meant words of advice: OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . 8 CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 It is important to read through these instructions carefully before using the refrigerator.
OPERATING INSTRUCTIONS 7. When the flame lights, the sparking stops automatically and the switch stops flashing. CONTROLS 8. Keep the (D) button pressed for a further 10 to 15 seconds to active the flame failure device, then release it. The refrigerator can be run on either 230 V, 12 V or LP gas. Changing between these modes of operation is carried out by means of the controls of the control panel shown in fig 3. If you have Model RM 4400 proceed as follows: 3.
On 12 V operation the refrigerator works continuously. When the ice has melted, wipe the refrigerator dry and restart it. Place the food items back inside but wait until the refrigerator is cold before making ice cubes. On LP gas operation the refrigerator temperature is regulated by the gas thermostat (E), which should be set at 3-5. If a lower (colder) temperature is desired, set the thermostat to a higher figure.
If the refrigerator is not cold enough it may be because: TECHNICAL DATA 1. The ventilation is inadequate owing to reduced area of the ventilation passages (partial blockage of grilles from wire mesh etc). Overall dimensions, refrigerator . . . RM4400/4401 Height . . . . . . . . . . . . . . . . . . . . . . . .805 mm Width . . . . . . . . . . . . . . . . . . . . . . . .525 mm Depth (incl. cooling unit) without door. . . . . . . . . . . . .494 mm with door. . . . . . . . . . . . . . . .533 mm 2.
BUILDING-IN Ventilation grilles Fig. 2 The refrigerator is intended for installation in a caravan or motorhome, and the description relates to this application. The openings in the caravan wall must be fitted with Electrolux ventilation systems. Fitting the grilles, model A 1620, which were specially developed by Electrolux for this purpose (shown as D in fig. 6). It is a good idea, to install the frame R 1640 (A in the same figure), at the same time.
The gas installation should only be carried out by an authorised gas fitter. WARNING! THIS APPLIANCE MUST BE EARTHED. In the United Kingdom, the plug or circuit to the refrige-rator must be fitted with a fuse not greater than 5 amps. If a 13 amp.(B.S.1363) fused plug is used, it should be fitted with a 3 amp. fuse. In other countries, the fuse rating will depend upon the voltage and local practice. The supply pipe should preferably be of copper.