OPERATING AND INSTALLATION INSTRUCTIONS FOR ELECTROLUX REFRIGERATORS INTRODUCTION CONTENTS We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it, but first a few well-meant words of advice: OPERATING INSTRUCTIONS ........................... 12 It is important to read through these instructions carefully before using the refrigerator.
OPERATING INSTRUCTIONS 5. CONTROLS 6. A B C D When the flame lights, the sparking stops automatically and the lamp stops flashing. Hold the button (C) an additional 10-15 seconds to activate the flame failure device, then release it. If the lamp start flashing again, repeat step 4-6. To terminate gas operation, turn the knob (A) to "OFF" position. 230-240 V operation Before operating the refrigerator, check that the voltage stated on the data plate is the same as the main voltage in use. • • FIG.
ICE MAKING HEATING CABLE It is practical to make ice during the night - then the refrigerator is less demanded and the cooling unit has more reserves. Fill the ice tray to just below the brim with drinking water and place it on the freezer shelf. It is possible to make ice faster by turning the control knob temporarily to its highest value but do not forget to turn it back to its regular setting afterwards as the refrigerator might otherwise become too cold.
If the refrigerator is not cooling sufficiently, the reason may be: 1. Inadequate ventilation of the cooling unit due to the intake and/or exhaust air vents being partly or completely blocked. 2. The evaporator is frosted up. 3. The thermostat setting is incorrect . 4. Gas pressure is incorrect - please check the pressure regulator on the gas container. 5. The ambient temperature is too high. 6. Too much food is loaded at one time. 7.
INSTALLATION/BUILDING-IN The refrigerator is intended for installation in a caravan or a motorhome, and the description relates to this application. The refrigerator must not be exposed to radiated heat from hot objects. Excessive heat irradiation impairs performance and leads to increased energy consumption.
VENTILATION OF THE UNIT Sealing gasket e.g. of V-type This piece is already on the refrigerator 60 Cut out opening for the side vent L500 is 341 x 451 mm. Cut out opening for the roof vent R500 is 87 x 507 mm Condenser Condenser L205 is 156 x 451 mm. min. ventilation height min. ventilation height Cut out opening for the side vent L500 is 341 x 451 mm Cut out opening for the side vent L500 is 341 x 451 mm 385 40 Batten attached to the floor FIG. 3a Sealing gasket e.g. of V-type 20 min.
It must be of a type approved for use with continuously operating bottled gas appliances, and have threaded compression connections throughout. PUSH-ON CONNECTIONS MUST NOT BE USED (We do not recommend the use of "rubber" type flexible tubing for connecting permanently operating appliances of this type in the United Kingdom). All connectors etc.
Interior light - bulb - change TECHNICAL DATA If the bulb has to be replaced, proceed as follows: 1. Remove the cover from the lamp body by pushing it backwards. 2. Remove the bulb. 3. Put in a new bulb (12 V, max. 5 W). Spare part number for bulb: 200 72 90-03. 4. Push the lamp cover back in place. RM 6501 Overall dimensions, refrigerator Height (incl. controls) .................. Width .......................................... Depth (incl. cooling unit) with door .....................................