Installation manual

16
Installation
5
5
From machine No. T4250 4250/101240–
T4350 4350/100825–
Reversing door
The loading door is reversible if it does not open
to the desired side.
Reversing
1. Disconnect the power supply to the dryer.
2. Open the operating panel.
3. Demountthelterdoor.
4. Unscrew the door and the front panel.
5. Unscrew the cover plate.
6. Demountthemagneticswitchwithttings.
7. Squeeze out the black strip which is mounted
in the back plate of the component unit
8. Run the cables including the black strip be-
hind the back plate and across the drum.
9. The black strip must be mounted in the hole
on the opposite side.
10. Unscrew the magnetic switch holder.
11. Move dummy plugs B in the side panel to the
opposite side.
12. Mount holder with magnetic switch on the
opposite side, use holes C.
Note! When turning the bracket the wires
are facing downwards. Lead them upwards
towards the operating panel and fasten them
with cable strips.
13. Move speed nuts to the opposite side.
14. Mount the cover plate.
15. Check that all 4 terminal strips are
mounted on the casing.
16. Reverse the front panel and the door and
then mount them.
Check that the felt joint is in good condition.
17. Close the operating panel and mount the
lterdoor.
W00056A
B
B