External connection - 100 mA
A special connection terminal is located on the
connection console.
The terminal for external control is equipped with
110V/max.100mA and is intended solely for the
operation of a contactor (external control of a
fan).
Max. connection 100mA.
Gnd. must not be used for earthing of external
board.
External connection - 1.25 A
If the dryer, from factory, is equipped with an ex-
ternal control with a max. 230V/1.25A connection
this connection (1.25A) can be used as connec-
tion of an external fan.
Mount cable for external connection on con-
tactor K7 in K7-2 and K7-4. Connect earth con-
ductor to earth terminal in terminal for external
connection.
Max. connection 1.25A.
To be carried out by qualied personnel
W00081, 84
5
W00082
6
External connection
Max. 1.25A