Service manual

43
Troubleshooting
Fault code 60, ACTUATOR CIRCUIT
The DLCU processor controls the door lock actuator coil. The DLCU pro-
cessor checks continuously that the coil is engaged. DLCU can detect a
break in the circuit (>50 kohm) (DLCU cannot detect a short in the circuit).
If there is a break in the actuator circuit, CPU will be notified; the fault
message will disappear if the fault ceases.
CPU reads the fault message when the program starts and finishes and
generates a fault code, the fault message is ignored between these two
occasions.
Reason:
•Thefaultcanbecausedbyabreakinthecablesbetweenthehatchlock
and the CPU, or caused by a fault in the hatch lock solenoid.
•FaultorbreakintheCPUcircuits.
Action:
•Ifthefaultreturnsafterareset,andisnotcausedbyafaultinthehatch
lock or the cables for the hatch lock, change the CPU.