Service manual

64
COINVALUE1 and 2
Specify with the knob the value (0 999) for the respective coin
slot.
Forexample: Coin1,1=1EURO
Coin2,5=5EURO
Coin1,50=50Cent
Coin2,100=1EURO
Setting the price to 300 and selecting COLON
WHEN PRICE will display the price as 3:00.
DOT WHEN PRICE
On machines with coin counter, the price can be displayed with or
without dot (0:00 or 000).
Yes = The dot is displayed.
No = The dot is not displayed.
TIMEOUT,DISPLAY,SEC
Specify with the knob the time after which the machine should
reset a program selection that has not started. The time is given in
steps of 10 seconds; 0 - 2550 seconds.
TIMEOUT,ENDBUZZ.SEC
Specify with the knob the time during which the buzzer should
sound at the end of the program unless the buzzer is turned off
manually. The time is given in seconds; 0 - 255.
TIMEOUT,PAUSBUZZ.SEC
Specify with the knob the time during which the buzzer should
sound for a pause unless the pause is interrupted manually. The
time is given in seconds; 0 - 255.
MAX FILL TIME, SEC
Specify with the knob the maximum time (in seconds, 0 - 2550)
it should take to fill the machine with water to the programmed
level.
If the water has not reached the correct level within the set time,
the ”NO WATER” fault message will appear on the display.