Service manual

66
OFFS.LEVELREADINGMM
The value set is subtracted from the ACTUAL value in mm in order to com-
pensate for the distance between the level recess and the bottom of the
inner drum. Once this has been set, the water level above the bottom of
the inner drum, etc. can be read.
DISPLAYWARNING,SEC
Specify with the knob the number of seconds the warnings are to be dis-
played. Warnings are e.g. empty tank alarm from detergent that is shown
each time a wash program is displayed.
The time is given in steps of 1 second in the range 0 -255 seconds.
FLUSHDELAY,LIQ.SEC
Delay time for flushing of detergent once dosing of liquid detergent is com-
plete.
The time is given in steps of 1 second in the range 0 -255 seconds.
FLUSHON,LIQ.SEC
Rinse times for rinsing detergent after the drum has been filled with water.
The time is given in steps of 1 second in the range 0 -255 seconds.
FLUSHDELAY,POWD.SEC
Delay for rinsing detergent after the drum has been filled with water.
The time is given in steps of 1 second in the range 0 -255 seconds.
Program unit